Severe bradycardia and hypotension after connecting negative pressure to the subgaleal drain during craniotomy closure.
Karamchandani, K; Chouhan, R S; Bithal, P K; Dash, H H.
Afiliación
  • Karamchandani K; Department of Neuroanaesthesia, All India Institute of Medical Sciences Ansari Nagar, New Delhi-110029, India.
Br J Anaesth ; 96(5): 608-10, 2006 May.
Article en En | MEDLINE | ID: mdl-16547089
ABSTRACT
Negative pressure drainage systems are often used after craniotomy for evacuation of potential bleeding. There are several reports of haemodynamic disturbances with epidural negative pressure drainage, but such reports are very few for subgaleal drains placed over the bone flap. We report a case in which a patient developed severe cardiovascular disturbances after the vacuum drainage was connected to a subgaleal drain after craniotomy for aneurysm clipping. The patient had no significant cardiac history, had an uneventful intra-operative course and yet developed bradycardia and hypotension, which were reproducible and severe enough to require atropine administration. Anaesthetists must be aware of these effects, so that they can anticipate and treat such complications.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Complicaciones Posoperatorias / Bradicardia / Craneotomía / Hipotensión Límite: Aged / Female / Humans Idioma: En Revista: Br J Anaesth Año: 2006 Tipo del documento: Article País de afiliación: India
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Complicaciones Posoperatorias / Bradicardia / Craneotomía / Hipotensión Límite: Aged / Female / Humans Idioma: En Revista: Br J Anaesth Año: 2006 Tipo del documento: Article País de afiliación: India
...