Your browser doesn't support javascript.
loading
Percutaneous ipsilateral portal vein embolization using a modified four-lumen balloon catheter with fibrin glue: initial clinical experience.
Gibo, Masaki; Unten, Shinobu; Yogi, Akira; Nakayama, Tadashi; Ayukawa, Yuichirou; Gibo, Shinji; Murayama, Sadayuki; Takara, Makoto; Shiraishi, Masayuki.
Afiliación
  • Gibo M; Department of Radiology, Graduate School of Medical Science, University of Ryukyus, 207 Uehara, Nishihara-cho, Okinawa, 903-0215, Japan. zf-1@umin.ac.jp
Radiat Med ; 25(4): 164-72, 2007 May.
Article en En | MEDLINE | ID: mdl-17514367
PURPOSE: The purpose of the present study was to show the feasibility and safety of ipsilateral portal vein embolization (PVE) using an improved four-lumen balloon catheter with fibrin glue. MATERIALS AND METHODS: To improve the ipsilateral PVE with fibrin glue, we modified a commercially available four-lumen balloon catheter to create a catheter comprising one lumen with a catheter tip for a guidewire, one lumen for an occlusion balloon, and two lumens, each with a side-hole just proximal to the balloon. Eight patients had hepatobiliary disease (three with bile duct carcinoma, two with gallbladder carcinoma, one with hepatocellular carcinoma, one with Caroli disease, and one with metastatic carcinoma). RESULTS: All embolization procedures were technically successful. After embolization, the volume of the future remnant liver increased a mean of 131%. There was no inadvertent embolization of portal vein branches and no major procedure-related complications. CONCLUSION: Our method is potentially easier and safer than the traditional ipsilateral method with fibrin glue using a three-lumen balloon catheter because the fourth lumen makes possible the use of a guidewire to access the targeted portal vein and measurement of any portal vein pressure elevation following PVE via the fourth lumen.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vena Porta / Carcinoma / Catéteres de Permanencia / Adhesivo de Tejido de Fibrina / Neoplasias Nasofaríngeas / Oclusión con Balón / Neoplasias del Sistema Digestivo Tipo de estudio: Evaluation_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Radiat Med Asunto de la revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR / NEOPLASIAS / RADIOTERAPIA Año: 2007 Tipo del documento: Article País de afiliación: Japón Pais de publicación: Japón
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vena Porta / Carcinoma / Catéteres de Permanencia / Adhesivo de Tejido de Fibrina / Neoplasias Nasofaríngeas / Oclusión con Balón / Neoplasias del Sistema Digestivo Tipo de estudio: Evaluation_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Radiat Med Asunto de la revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR / NEOPLASIAS / RADIOTERAPIA Año: 2007 Tipo del documento: Article País de afiliación: Japón Pais de publicación: Japón