Your browser doesn't support javascript.
loading
Quantitative assessment of pulmonary insufficiency by Doppler echocardiography in patients with adult congenital heart disease.
Yang, Hua; Pu, Min; Chambers, Charles E; Weber, Howard S; Myers, John L; Davidson, William R.
Afiliación
  • Yang H; Department of Cardiology, University of Toronto, Toronto, Ontario, Canada.
J Am Soc Echocardiogr ; 21(2): 157-64, 2008 Feb.
Article en En | MEDLINE | ID: mdl-17869058
ABSTRACT
We determined the utility of continuous wave (CW) Doppler for quantification of pulmonary insufficiency (PI) confirmed by pulmonary angiography in patients with postoperative adult congenital heart disease. A total of 41 patients with PI were divided into two groups on the basis of PI severity by pulmonary angiography group A (n = 27) with severe PI and group B (n = 14) with mild or moderate PI. Nine patients in group A had pulmonic valve replacement and reverted to mild PI after surgery. Their pre- and postoperative data were compared. All underwent a two-dimensional/Doppler study with interrogation of the PI jet for jet width by color Doppler and peak flow velocity, deceleration time (DT), pressure half-time (PHT), diastolic period (DP), and PI flow time (FT) by CW Doppler. The no-flow time (NFT), NFT/FT ratio, and NFT/DP fraction were calculated. Group A had a larger right ventricle (4.1 +/- 0.9 vs. 3.5 +/- 0.6 cm, P = .033), higher PI peak velocity (2.1 +/- 0.5 vs. 1.7 +/- 0.5 m/s, P = .04), shorter DT (261 +/- 61 vs. 317 +/- 83 ms, P = .018) and PHT (76 +/- 29 vs. 132 +/- 53, P < .0001), longer NFT (146 +/- 66 vs. 40 +/- 42 ms, P < .0001), and higher ratios of NFT/FT (46% +/- 27% vs. 13% +/- 14%, P < .0001) and NFT/DP (29% +/- 13% vs. 10% +/- 9%, P < .0001). The PHT and DT lengthened, and the NFT shortened in patients who underwent pulmonic valve replacement (all P < .05). By binary logistic regression, NFT and PHT were the best predictors for severe PI. An NFT of 80 ms had 84% sensitivity and 93% specificity, and a PHT of 100 ms had 93% sensitivity and 93% specificity for identifying angiographically severe PI. CW Doppler accurately distinguishes severe from lesser degrees of PI in patients with postoperative adult congenital heart disease.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Insuficiencia de la Válvula Pulmonar / Ecocardiografía Doppler en Color / Cardiopatías Congénitas Tipo de estudio: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: J Am Soc Echocardiogr Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2008 Tipo del documento: Article País de afiliación: Canadá
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Insuficiencia de la Válvula Pulmonar / Ecocardiografía Doppler en Color / Cardiopatías Congénitas Tipo de estudio: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: J Am Soc Echocardiogr Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2008 Tipo del documento: Article País de afiliación: Canadá