The reproducibility of a clinical grading system of motor control in patients with low back pain.
Sedaghat, Negin; Latimer, Jane; Maher, Christopher; Wisbey-Roth, Trish.
Afiliación
  • Sedaghat N; Discipline of Physiotherapy, School of Health Sciences, University of Sydney, NSW, Australia.
J Manipulative Physiol Ther ; 30(7): 501-8, 2007 Sep.
Article en En | MEDLINE | ID: mdl-17870418
ABSTRACT

OBJECTIVE:

Over the past decade, instrument and palpation methods for quantifying the activation and recruitment of the transversus abdominis and lumbar multifidus have been proposed. Palpation methods however have recently been described and therefore have been subjected to little evaluation. One such palpation method is the Wisbey-Roth grading system. The recruitment of the transversus abdominis and lumbar multifidus is assessed in a series of functional body positions and movements. The ability to recruit these muscles is quantified by assigning 1 of 6 defined grades. The purpose of this study was to investigate the reproducibility of this grading system.

METHODS:

A total of 2 meetings and 3 pilot trials were held with raters before commencement of the study to establish an agreed grading system protocol. Interrater reproducibility was investigated using a Latin square repeated measures design. Thirty-four subjects (62% male and 38% female; age range, 15-70 years) with a history of low back pain participated. A total of 4 practicing physiotherapists and 1 sports medicine physician graded subjects using the Wisbey-Roth grading system protocol.

RESULTS:

Pair-wise weighted kappa values ranged from -0.01 (95% confidence interval [CI], -0.33 to 0.31) to 0.56 (95% CI, 0.25 to 0.87), with average weighted kappa being 0.29. The intraclass correlation coefficient (2,1) was 0.30 (95% CI, 0.15 to 0.48), and the standard error of the measurement was 1.6 units.

CONCLUSIONS:

The Wisbey-Roth grading system shows fair to poor reproducibility between raters. Therefore, it should not be used to exchange meaningful information between clinicians. Recommendations are made for further research and toward improving its reproducibility.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Palpación / Reclutamiento Neurofisiológico / Dolor de la Región Lumbar / Músculo Esquelético Tipo de estudio: Guideline Límite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Manipulative Physiol Ther Año: 2007 Tipo del documento: Article País de afiliación: Australia
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Palpación / Reclutamiento Neurofisiológico / Dolor de la Región Lumbar / Músculo Esquelético Tipo de estudio: Guideline Límite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Manipulative Physiol Ther Año: 2007 Tipo del documento: Article País de afiliación: Australia