Your browser doesn't support javascript.
loading
From 3D to 4D imaging: is that useful for interventional cardiac electrophysiology?
Fenici, R; Brisinda, D.
Afiliación
  • Fenici R; Clinical Physiology - Biomagnetism Research Center, Catholic University of Sacred Heart, Largo A. Gemelli 8, 00168 Rome, Italy.
Article en En | MEDLINE | ID: mdl-18003380
Three-dimensional electroanatomical imaging is increasingly used in interventional cardiac electrophysiology, to guide catheter ablation of cardiac arrhythmias. At the same time, there is a growing interest for non-invasive methods, such as magnetocardiographic mapping (MCG), to localize the arrhythmogenic substrates, to test their reproducibility and to plan the most appropriate interventional approach. So far electroanatomical imaging has relayed on static mathematical modeling of the heart and more recently on direct merging with three-dimensional rendering of cardiac anatomy from multidetector computer tomography or magnetic resonance imaging. Merging electrophysiological information with static anatomical structures, can surely be a source of uncertainty for MCG-based pre-interventional localization of the arrhythmogenic substrate and causes mismatch between the real-time imaging of moving catheters and the static geometry of the cardiac chambers reconstructed with invasive electroanatomical imaging. The implementation of recent realistic numerical models of the beating heart in a breathing thorax can improve accuracy and fill the gap between non-invasive and interventional electroanatomical imaging.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arritmias Cardíacas / Ablación por Catéter / Mapeo del Potencial de Superficie Corporal / Imagenología Tridimensional / Cirugía Asistida por Computador Tipo de estudio: Evaluation_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Annu Int Conf IEEE Eng Med Biol Soc Año: 2007 Tipo del documento: Article País de afiliación: Italia Pais de publicación: Estados Unidos
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arritmias Cardíacas / Ablación por Catéter / Mapeo del Potencial de Superficie Corporal / Imagenología Tridimensional / Cirugía Asistida por Computador Tipo de estudio: Evaluation_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Annu Int Conf IEEE Eng Med Biol Soc Año: 2007 Tipo del documento: Article País de afiliación: Italia Pais de publicación: Estados Unidos