Your browser doesn't support javascript.
loading
Does carotid stent cell design matter?
Schillinger, Martin; Gschwendtner, Manfred; Reimers, Bernhard; Trenkler, Johannes; Stockx, Luc; Mair, Johann; Macdonald, Sumaira; Karnel, Franz; Huber, Kurt; Minar, Erich.
Afiliación
  • Schillinger M; Department of Angiology, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria. martin.schillinger@meduniwien.ac.at
Stroke ; 39(3): 905-9, 2008 Mar.
Article en En | MEDLINE | ID: mdl-18239162
ABSTRACT
BACKGROUND AND

PURPOSE:

Carotid stent cell design has recently been suggested to be a determinant of periprocedural and early postprocedural neurologic complications. We investigated the impact of closed- versus open-cell stent design on neurologic adverse events and mortality after carotid artery stenting.

METHODS:

We studied 1684 consecutive patients (1010 asymptomatic, 674 symptomatic) from 10 European centers who underwent carotid artery stenting with either closed-cell (n=859, 51%) or open-cell (n=825, 49%) design stents. Rates of transient ischemic attack, stroke, and death on the day of the procedure (acute events) and from day 1 to day 30 after the procedure (subacute events) were analyzed (95% CIs).

RESULTS:

Combined transient ischemic attack, stroke, or death rates, and stroke or death rates within 30 days of treatment were 6.1% (95% CI, 5.0 to 7.2) and 3.1% (95% CI, 2.3 to 3.9) for the closed-cell design versus 4.1% (95% CI, 3.2 to 5.0) and 2.4% (95% CI, 1.7 to 3.1) for the open-cell design stents (P=0.077, P=0.38), respectively, without significant differences in asymptomatic and symptomatic patients. By propensity-score-adjusted multivariable analysis, the open-cell carotid stent design was not associated with a differential risk for combined acute and subacute neurologic complications compared with closed-cell stents (adjusted odds ratio=0.84, P=0.53). When analyzed separately, the risk for acute events on the day of the procedure (adjusted odds ratio=0.83, P=0.57) and the risk for subacute events at days 1 to 30 (adjusted odds ratio=1.61, P=0.51) also were not significantly different between the groups.

CONCLUSIONS:

Current data do not support the superiority of a specific carotid stent cell design with respect to neurologic complications, stroke, and mortality risk.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Enfermedades de las Arterias Carótidas / Stents / Enfermedades del Sistema Nervioso Tipo de estudio: Clinical_trials / Etiology_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Stroke Año: 2008 Tipo del documento: Article País de afiliación: Austria

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Enfermedades de las Arterias Carótidas / Stents / Enfermedades del Sistema Nervioso Tipo de estudio: Clinical_trials / Etiology_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Stroke Año: 2008 Tipo del documento: Article País de afiliación: Austria