Your browser doesn't support javascript.
loading
Comparison of long-term angiographic follow-up after sirolimus-eluting stent and bare-metal stent implantation.
Shiode, Nobuo; Shirota, Kinya; Goto, Kenji; Sairaku, Akinori; Mikami, Shinya; Kato, Yasuko; Suenari, Kazuyoshi; Ishi, Hiroshige.
Afiliación
  • Shiode N; Department of Cardiology, Matsue Red Cross Hospital, Matsue, Japan. nobucode.0317@kfd.biglobe.ne.jp
Intern Med ; 47(4): 201-4, 2008.
Article en En | MEDLINE | ID: mdl-18277017
ABSTRACT

BACKGROUND:

The sirolimus-eluting stent (SES) has dramatically reduced the rate of restenosis in comparison to that with the bare-metal stent (BMS). In previous studies, the minimal luminal diameter (MLD) of lesions treated with a BMS was shown to improve from 6 months to 1 year.

METHODS:

To evaluate 6-month and 1-year outcomes, angiographic follow-up data were analyzed for 285 patients (451 lesions) who underwent successful SES implantation compared to follow-up data for 2,561 patients (3,367 lesions) who underwent BMS implantation.

RESULTS:

Angiographic follow-up was performed at 6 months for 396 SES-treated lesions and 2,628 BMS-treated lesions and at 1 year for 322 SES-treated lesions and 1,540 BMS-treated lesions. The 6-month angiographic restenosis rate was significantly lower for SES-treated lesions than for BMS-treated lesions (4.8% vs. 23.4%, p<0.01). From immediately after stent implantation to 6 months, quantitative coronary angiography revealed a significantly larger decrease in MLD of BMS-treated lesions than in MLD of SES-treated lesions (p<0.01). In BMS-treated lesions in which repeat revascularization was not performed at 6 months, MLD increased significantly from 2.08+/-0.63 mm at 6 months to 2.11+/-0.61 mm at 1 year (p<0.01). In SES-treated lesions, however, MLD decreased significantly from 2.55+/-0.56 mm at 6 months to 2.44+/-0.61 mm at 1 year (p<0.05).

CONCLUSIONS:

From 6 months to 1 year, stenosis of BMS-treated lesions regressed, but stenosis of SES-treated lesions progressed.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Sirolimus / Estenosis Coronaria / Stents Liberadores de Fármacos Tipo de estudio: Observational_studies / Prognostic_studies Límite: Aged / Humans Idioma: En Revista: Intern Med Asunto de la revista: MEDICINA INTERNA Año: 2008 Tipo del documento: Article País de afiliación: Japón
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Sirolimus / Estenosis Coronaria / Stents Liberadores de Fármacos Tipo de estudio: Observational_studies / Prognostic_studies Límite: Aged / Humans Idioma: En Revista: Intern Med Asunto de la revista: MEDICINA INTERNA Año: 2008 Tipo del documento: Article País de afiliación: Japón
...