Your browser doesn't support javascript.
loading
Sulfated and sulfonated polysaccharide as chiral stationary phases for capillary electrochromatography and capillary electrochromatography-mass spectrometry.
Zheng, Jie; Bragg, William; Hou, Jingguo; Lin, Na; Chandrasekaran, Sekar; Shamsi, Shahab A.
Afiliación
  • Zheng J; Department of Chemistry, Center of Biotechnology and Drug Design, Georgia State University, Atlanta, GA 30303, USA.
J Chromatogr A ; 1216(5): 857-72, 2009 Jan 30.
Article en En | MEDLINE | ID: mdl-19108837
ABSTRACT
The applications of polysaccharide phenyl carbamate derivatives as chiral stationary phases (CSPs) for capillary electrochromatography (CEC) are often hindered by longer retention times, especially using a normal-phase (NP) eluent due to very low electroosmotic flow (EOF). Therefore, in this study, we propose an approach for the aforementioned problems by introducing two new types of negatively charged sulfate and sulfonated groups for polysaccharide CSPs. These CSPs were utilized to pack CEC columns for enantioseparation with a NP eluent. Compared to conventional cellulose tris(3,5-dimethylphenyl carbamate) or CDMPC CSPs, the sulfated CDMPC CSP (sulfur content 4.25%, w/w) shortened the analysis time up to 50% but with a significant loss of enantiomeric resolution (approximately 60%). On the other hand, the sulfonated CDMPC CSP (sulfur content 1.76%, w/w) not only provided fast throughput but also maintained excellent resolving power. In addition, its synthesis is much more straightforward than the sulfated one. Furthermore, we studied several stationary phase parameters (CSP loading and silica gel pore size) and mobile phase parameters (including type of mobile phase and its composition) to evaluate the throughput and enantioselectivity. Using the optimized conditions, a chiral pool containing 66 analytes was screened to evaluate the enantioselectivity under three different mobile phase modes (i.e., NP, polar organic phase (POP) and reversed-phase (RP) eluents). Among these mobile phase modes, the RP mode showed the highest success rate, whereas some degree of complementary enantioselectivity was observed with NP and POP. Finally, the feasibility of applying this CSP for CEC-MS enantioseparation using internal tapered column was evaluated with NP, POP and RP eluents. In particular, the NP-CEC-MS provided significantly enhanced sensitivity when methanol was replaced with isopropanol in the sheath liquid. Using aminoglutethimide as model chiral analyte, all three modes of CEC-MS demonstrated excellent durability as well as excellent reproducibility of retention time and enantioselectivity.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Polisacáridos / Sulfatos / Ácidos Sulfónicos / Espectrometría de Masa por Ionización de Electrospray / Electrocromatografía Capilar Tipo de estudio: Diagnostic_studies / Prognostic_studies Idioma: En Revista: J Chromatogr A Año: 2009 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Polisacáridos / Sulfatos / Ácidos Sulfónicos / Espectrometría de Masa por Ionización de Electrospray / Electrocromatografía Capilar Tipo de estudio: Diagnostic_studies / Prognostic_studies Idioma: En Revista: J Chromatogr A Año: 2009 Tipo del documento: Article País de afiliación: Estados Unidos
...