Your browser doesn't support javascript.
loading
Variation of angle parameters in asians: an anterior segment optical coherence tomography study in a population of singapore malays.
Amerasinghe, Nishani; Foster, Paul J; Wong, Tien Yin; Htoon, Hla Myint; He, Mingguang; Shen, Sunny Y; Aung, Han T; Saw, Seang-Mei; Aung, Tin.
Afiliación
  • Amerasinghe N; Singapore National Eye Centre, Singapore.
Invest Ophthalmol Vis Sci ; 50(6): 2626-31, 2009 Jun.
Article en En | MEDLINE | ID: mdl-19182259
PURPOSE: To assess variations in angle parameters using anterior segment optical coherence tomography (AS-OCT) and to investigate demographic, ocular and systemic associations of angle width. METHODS: This was a substudy of a population based, cross-sectional survey of 3280 (78.7% response rate) Malay people aged 40 to 80 years in Singapore. All participants underwent a standardized interview and ocular and systemic examination. AS-OCT was performed on 291 consecutive patients in standardized dark conditions. Angle opening distance (AOD-500) and trabecular-iris space area (TISA-500) 500 microm from the scleral spur were determined for the nasal and temporal angles. Anterior chamber depth (ACD) was also measured. RESULTS: AS-OCT measurements were analyzed in 239 (82.1%) right eyes. Mean AOD 500 was smaller in women than in men, both nasally (0.255 vs. 0.293 mm, P = 0.026) and temporally (0.245 vs. 0.286 mm, P = 0.023). Mean TISA-500 was smaller in women in the nasal quadrant only (0.104 vs. 0.117 mm, P = 0.035). Mean ACD was smaller in women than in men (2.71 vs. 2.87 mm, P = 0.001). Multiple linear regression showed that axial length and ACD were significantly associated with AOD-500 and TISA-500 both nasally (adjusted R(2) = 0.34 for AOD-500 and 0.20 for TISA-500) and temporally (adjusted R(2) = 0.35 for AOD-500 and 0.24 for TISA-500). Body mass index, HbA(1c), systolic blood pressure, intraocular pressure, cup-to-disc ratio, and central corneal thickness were not significantly associated with AOD-500, TISA-500, or ACD. CONCLUSIONS: In this Malay population, angle width measured by AS-OCT was smaller in women than in men, and in eyes with shorter axial length and shallower ACD.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tomografía de Coherencia Óptica / Pueblo Asiatico / Segmento Anterior del Ojo Tipo de estudio: Observational_studies / Prevalence_studies / Risk_factors_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Región como asunto: Asia Idioma: En Revista: Invest Ophthalmol Vis Sci Año: 2009 Tipo del documento: Article País de afiliación: Singapur Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tomografía de Coherencia Óptica / Pueblo Asiatico / Segmento Anterior del Ojo Tipo de estudio: Observational_studies / Prevalence_studies / Risk_factors_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Región como asunto: Asia Idioma: En Revista: Invest Ophthalmol Vis Sci Año: 2009 Tipo del documento: Article País de afiliación: Singapur Pais de publicación: Estados Unidos