Influence of computer-aided detection false-positives on reader performance and diagnostic confidence for CT colonography.
AJR Am J Roentgenol
; 192(6): 1682-9, 2009 Jun.
Article
en En
| MEDLINE
| ID: mdl-19457835
OBJECTIVE: The objective of our study was to investigate whether an increasing number of computer-aided detection (CAD) false-positives decreases reader sensitivity, specificity, and confidence for nonexpert readers of CT colonography (CTC). MATERIALS AND METHODS: Fifty CTC data sets (29 men; mean age, 65 years), 25 of which contained 35 polyps > or = 5 mm, were selected in which CAD had 100% polyp sensitivity at two sphericity settings (0 and 75) but differed in the number of false-positives. The data sets were read by five readers twice: once at each sphericity setting. Sensitivity, specificity, report time, and confidence before and after second-read CAD were compared using the paired exact and Student's t test, respectively. Receiver operating characteristic (ROC) curves were generated using reader confidence (1-100) in correct case classification (normal or abnormal). RESULTS: CAD generated a mean of 42 (range, 3-118) and 15 (range, 1-36) false-positives at a sphericity of 0 and 75, respectively. CAD at both settings increased per-patient sensitivity from 82% to 87% (p = 0.03) and per-polyp sensitivity by 8% and 10% for a sphericity of 0 and 75, respectively (p < 0.001). Specificity decreased from 84% to 79% (sphericity 0 and 75, p = 0.03 and 0.07). There was no difference in sensitivity, specificity, or reader confidence between sphericity settings (p = 1.0, 1.0, 0.11, respectively). The area under the ROC curve was 0.78 (95% CI, 0.70-0.86) and 0.77 (0.68-0.85) for a sphericity of 0 and 75, respectively. CAD added a median of 4.4 minutes (interquartile range [IQR], 2.7-6.5 minutes) and 2.2 minutes (IQR, 1.2-4.0 minutes) for a sphericity of 0 and 75, respectively (p < 0.001). CONCLUSION. CAD has the potential to increase the sensitivity of readers inexperienced with CTC, although specificity may be reduced. An increased number of CAD-generated false-positives does not negate any beneficial effect but does reduce efficiency.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Reconocimiento de Normas Patrones Automatizadas
/
Inteligencia Artificial
/
Interpretación de Imagen Radiográfica Asistida por Computador
/
Intensificación de Imagen Radiográfica
/
Actitud del Personal de Salud
/
Pólipos del Colon
/
Colonografía Tomográfica Computarizada
Tipo de estudio:
Diagnostic_studies
/
Evaluation_studies
/
Prognostic_studies
Límite:
Aged
/
Female
/
Humans
/
Male
Idioma:
En
Revista:
AJR Am J Roentgenol
Año:
2009
Tipo del documento:
Article
País de afiliación:
Reino Unido
Pais de publicación:
Estados Unidos