Performance of FASTPlaqueTB and a modified protocol in a high HIV prevalence community in South Africa.
Int J Tuberc Lung Dis
; 13(6): 791-3, 2009 Jun.
Article
en En
| MEDLINE
| ID: mdl-19460258
Modifications in the FASTPlaqueTB test protocol have resulted in an increase in the analytical limits of detection. This study investigated whether the performance of a modified prototype was able to increase the detection of smear-negative, culture-positive sputum samples as compared to the first generation FASTPlaqueTB test. Modifications to the FASTPlaqueTB did result in increased detection of smear-negative samples, but this was associated with a decrease in the specificity of the test. Before the FASTPlaqueTB can be considered as a viable replacement for smear microscopy and culture for the identification of tuberculosis, further work is required to resolve the performance issues identified in this study.
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Tuberculosis Pulmonar
/
Pruebas de Sensibilidad Microbiana
/
Infecciones por VIH
Tipo de estudio:
Prevalence_studies
/
Prognostic_studies
/
Risk_factors_studies
Límite:
Humans
País/Región como asunto:
Africa
Idioma:
En
Revista:
Int J Tuberc Lung Dis
Año:
2009
Tipo del documento:
Article
País de afiliación:
Sudáfrica
Pais de publicación:
Francia