Your browser doesn't support javascript.
loading
ABC/2 for rapid clinical estimate of infarct, perfusion, and mismatch volumes.
Sims, J R; Gharai, L Rezai; Schaefer, P W; Vangel, M; Rosenthal, E S; Lev, M H; Schwamm, L H.
Afiliación
  • Sims JR; Department of Neurology, Massachusetts General Hospital, Harvard Medical School, Charlestown, 02129, USA. jsims@partners.org
Neurology ; 72(24): 2104-10, 2009 Jun 16.
Article en En | MEDLINE | ID: mdl-19528517
ABSTRACT

BACKGROUND:

Rapid and easy clinical assessments for volumes of infarction and perfusion mismatch are needed. We tested whether simple geometric models generated accurate estimates of these volumes.

METHODS:

Acute diffusion-weighted image (DWI) and perfusion (mean transit time [MTT]) in 63 strokes and established infarct volumes in 50 subacute strokes were measured by computerized planimetry. Mismatch was defined as MTT/DWI > or = 1.2. Observers, blinded to planimetric values, measured lesions in three perpendicular axes A, B, and C. Geometric estimates of sphere, ellipsoid, bicone, and cylinder were compared to planimetric volume by least-squares linear regression.

RESULTS:

The ABC/2 formula (ellipsoid) was superior to other geometries for estimating volume of DWI (slope 1.16, 95% confidence interval [CI] 0.94 to 1.38; R(2) = 0.91, p = 0.001) and MTT (slope 1.11, 95% CI 0.99 to 1.23; R(2) = 0.89, p = 0.001). The intrarater and interrater reliability for ABC/2 was high for both DWI (0.992 and 0.965) and MTT (0.881 and 0.712). For subacute infarct, the ABC/2 formula also best estimated planimetric volume (slope 1.00, 95% CI 0.98 to 1.19; R(2) = 0.74, p = 0.001). In general, sphere and cylinder geometries overestimated all volumes and bicone underestimated all volumes. The positive predictive value for mismatch was 92% and negative predictive value was 33%.

CONCLUSIONS:

Of the models tested, ABC/2 is reproducible, is accurate, and provides the best simple geometric estimate of infarction and mean transit time volumes. ABC/2 has a high positive predictive value for identifying mismatch greater than 20% and might be a useful tool for rapid determination of acute stroke treatment.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Infarto Encefálico / Imagen de Difusión por Resonancia Magnética Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Neurology Año: 2009 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Infarto Encefálico / Imagen de Difusión por Resonancia Magnética Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Neurology Año: 2009 Tipo del documento: Article País de afiliación: Estados Unidos
...