ABSTRACT

OBJECTIVE:

Localization of microadenomas in Cushing's disease may be difficult as in up to 45% of patients sellar MRI fails to detect a pituitary tumor. Intraoperative transsphenoidal ultrasound may identify microadenomas as hyperechoic structures. We report on the first 18 consecutive cases with intraoperative use of a new device for direct contact high-frequency-ultrasound in patients with Cushing's disease. PATIENTS AND TECHNIQUE 18 patients (14 female, 4 male, age 24-71 years) with typical endocrinological findings for Cushing's disease were included in the study. One macroadenoma and 13 microadenomas were suspected or identified preoperatively by MRI. In 4 cases, two of them with recurrent disease, sellar MRIs were negative. During transsphenoidal microsurgery an end fire ultrasound-probe (B-mode frequency range 7.5-13 Mhz, field of view 5 mm, penetration 20 mm) was introduced after opening of sellar floor. The pituitary gland was scanned in direct contact to the capsule.

RESULTS:

In 13 out of 17 cases (77%) with later on proven microadenomas high-frequency-ultrasound identified the tumors as hyperechoic masses, including 3 of the 4 cases with negative preoperative MRI. In 2 cases ultrasound correctly localized the tumor at a site different from MRI finding (MRI false positive). In the macroadenoma, identification of the border between tumor and anterior pituitary gland was not possible. In all 18 patients postoperative early decline of serum cortisol to subnormal levels confirmed remission of hypercortisolism (100%). Other pituitary functions were unaltered in 17 cases (94%).

CONCLUSIONS:

Intraoperative scanning of the pituitary gland with high-frequency-ultrasound probes may identify intrapituitary anatomy and pathologies even in MRI-negative cases. This may prevent extensive exploration of the gland with the risk of subsequent hypopituitarism.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias Hipofisarias / Adenoma / Ultrasonografía Intervencional / Hipersecreción de la Hormona Adrenocorticotrópica Pituitaria (HACT) / Microcirugia Tipo de estudio: Prognostic_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Exp Clin Endocrinol Diabetes Asunto de la revista: ENDOCRINOLOGIA Año: 2011 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias Hipofisarias / Adenoma / Ultrasonografía Intervencional / Hipersecreción de la Hormona Adrenocorticotrópica Pituitaria (HACT) / Microcirugia Tipo de estudio: Prognostic_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Exp Clin Endocrinol Diabetes Asunto de la revista: ENDOCRINOLOGIA Año: 2011 Tipo del documento: Article País de afiliación: Alemania