ABSTRACT

PURPOSE:

We compared the diagnostic accuracy of fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) and PET/magnetic resonance imaging (MRI) fusion images for gynecological malignancies. MATERIALS AND

METHODS:

A total of 31 patients with gynecological malignancies were enrolled. FDG-PET images were fused to CT, T1- and T2-weighted images (T1WI, T2WI). PET-MRI fusion was performed semiautomatically. We performed three types of evaluation to demonstrate the usefulness of PET/MRI fusion images in comparison with that of inline PET/CT as follows depiction of the uterus and the ovarian lesions on CT or MRI mapping images (first evaluation); additional information for lesion localization with PET and mapping images (second evaluation); and the image quality of fusion on interpretation (third evaluation).

RESULTS:

For the first evaluation, the score for T2WI (4.68 +/- 0.65) was significantly higher than that for CT (3.54 +/- 1.02) or T1WI (3.71 +/- 0.97) (P < 0.01). For the second evaluation, the scores for the localization of FDG accumulation showing that T2WI (2.74 +/- 0.57) provided significantly more additional information for the identification of anatomical sites of FDG accumulation than did CT (2.06 +/- 0.68) or T1WI (2.23 +/- 0.61) (P < 0.01). For the third evaluation, the three-point rating scale for the patient group as a whole demonstrated that PET/T2WI (2.72 +/- 0.54) localized the lesion significantly more convincingly than PET/CT (2.23 +/- 0.50) or PET/T1WI (2.29 +/- 0.53) (P < 0.01).

CONCLUSION:

PET/T2WI fusion images are superior for the detection and localization of gynecological malignancies.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Tomografía Computarizada por Rayos X / Medios de Contraste / Fluorodesoxiglucosa F18 / Tomografía de Emisión de Positrones / Neoplasias de los Genitales Femeninos Tipo de estudio: Diagnostic_studies / Evaluation_studies / Observational_studies / Prognostic_studies Límite: Adult / Aged / Aged80 / Female / Humans / Middle aged Idioma: En Revista: Jpn J Radiol Asunto de la revista: DIAGNOSTICO POR IMAGEM / RADIOLOGIA / RADIOTERAPIA Año: 2010 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Tomografía Computarizada por Rayos X / Medios de Contraste / Fluorodesoxiglucosa F18 / Tomografía de Emisión de Positrones / Neoplasias de los Genitales Femeninos Tipo de estudio: Diagnostic_studies / Evaluation_studies / Observational_studies / Prognostic_studies Límite: Adult / Aged / Aged80 / Female / Humans / Middle aged Idioma: En Revista: Jpn J Radiol Asunto de la revista: DIAGNOSTICO POR IMAGEM / RADIOLOGIA / RADIOTERAPIA Año: 2010 Tipo del documento: Article País de afiliación: Japón