Sequential changes in myocardial function after valve replacement for aortic stenosis by speckle tracking echocardiography.
Rost, Christian; Korder, S; Wasmeier, G; Wu, M; Klinghammer, L; Flachskampf, F A; Daniel, W G; Voigt, J-U.
Afiliación
  • Rost C; University of Erlangen, Erlangen, Germany. rost.christian@gmx.net
Eur J Echocardiogr ; 11(7): 584-9, 2010 Aug.
Article en En | MEDLINE | ID: mdl-20200001
AIMS: Regional myocardial function may change differently in different pathology. Speckle tracking echocardiography (STE) was applied to evaluate longitudinal, radial, and circumferential function in patients with aortic stenosis (AS) before, within 1 week, and 6 months after aortic valve replacement (AVR). METHODS AND RESULTS: In 40 consecutive patients with severe AS, we acquired apical four-, three-, and two-chamber views and standard short-axis view pre- and post-AVR and after 6 months. Longitudinal, radial, and circumferential (LS, RS, and CS) were calculated by commercial STE software. Further, we analysed diastolic myocardial function by measuring E/e' ratio. With AVR, valve area increased and remained stable at 6 months follow-up. Left ventricular mass was unchanged 1 week after AVR (270 +/- 58 g vs. 267 +/- 58 g, n.s.) but decreased significantly during the next 6 months (219 +/- 50 g, P < 0.05). Left ventricular ejection fraction remained unchanged. Strain values did not change significantly within 1 week after AVR but increased significantly after 6 months (LS by 16%, RS by 21%, and CS by 28% of baseline values). E/e' ratio was highly augmented before AVR (26.1 +/- 12.5) and decreased significantly 6 months after AVR (15.9 +/- 5.9). CONCLUSION: Myocardial function significantly recovers after replacing the stenosed aortic valve. However, there is a considerable difference between the response of longitudinal, radial, and circumferential function. Our data suggest that echocardiographic assessment of regional function is feasible and of potential clinical importance.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Válvula Aórtica / Estenosis de la Válvula Aórtica / Ecocardiografía / Disfunción Ventricular Izquierda / Implantación de Prótesis de Válvulas Cardíacas Tipo de estudio: Diagnostic_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Echocardiogr Asunto de la revista: CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Año: 2010 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Válvula Aórtica / Estenosis de la Válvula Aórtica / Ecocardiografía / Disfunción Ventricular Izquierda / Implantación de Prótesis de Válvulas Cardíacas Tipo de estudio: Diagnostic_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Echocardiogr Asunto de la revista: CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Año: 2010 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Reino Unido