Your browser doesn't support javascript.
loading
Absence of prosthesis-patient mismatch with the new generation of Edwards stented aortic bioprosthesis.
Wyss, Thomas R; Bigler, Marc; Stalder, Mario; Englberger, Lars; Aymard, Thierry; Kadner, Alexander; Carrel, Thierry P.
Afiliación
  • Wyss TR; Department of Cardiovascular Surgery, University Hospital, 3010 Bern, Switzerland.
Interact Cardiovasc Thorac Surg ; 10(6): 884-7; discussion 887-8, 2010 Jun.
Article en En | MEDLINE | ID: mdl-20233807
ABSTRACT
Prosthesis-patient mismatch (PPM) remains a controversial issue with the most recent stented biological valves. We analyzed the incidence of PPM after implantation of the Carpentier-Edwards Perimount Magna Ease aortic valve (PMEAV) bioprosthesis and assessed the early clinical outcome. Two hundred and seventy consecutive patients who received a PMEAV bioprosthesis between January 2007 and July 2008 were analyzed. Pre-, peri- and postoperative data were assessed and echocardiographic as well as clinical follow-up was performed. Mean age was 72+/-9 years, 168 (62.2%) were males. Fifty-seven patients (21.1%) were below 65 years of age. Absence of PPM, corresponding to an indexed effective orifice area >0.85 cm(2)/m(2), was 99.5%. Observed in-hospital mortality was 2.2% (six patients), with a predicted mortality according to the additive EuroSCORE of 7.6+/-3.1%. At echocardiographic assessment after a mean follow-up period of 150+/-91 days, mean transvalvular gradient was 11.8+/-4.8 mmHg (all valve sizes). No paravalvular leakage was seen. Nine patients died during follow-up. The Carpentier-Edwards PMEAV bioprosthesis shows excellent hemodynamic performance. This valve can be implanted in all sizes with an incidence of severe PPM below 0.5%.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Válvula Aórtica / Estenosis de la Válvula Aórtica / Bioprótesis / Prótesis Valvulares Cardíacas / Stents / Implantación de Prótesis de Válvulas Cardíacas Tipo de estudio: Prognostic_studies Límite: Aged / Aged80 / Animals / Female / Humans / Male / Middle aged Idioma: En Revista: Interact Cardiovasc Thorac Surg Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2010 Tipo del documento: Article País de afiliación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Válvula Aórtica / Estenosis de la Válvula Aórtica / Bioprótesis / Prótesis Valvulares Cardíacas / Stents / Implantación de Prótesis de Válvulas Cardíacas Tipo de estudio: Prognostic_studies Límite: Aged / Aged80 / Animals / Female / Humans / Male / Middle aged Idioma: En Revista: Interact Cardiovasc Thorac Surg Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2010 Tipo del documento: Article País de afiliación: Suiza