Characterization of the evanescent field profile and bound mass sensitivity of a label-free silicon photonic microring resonator biosensing platform.
Luchansky, Matthew S; Washburn, Adam L; Martin, Teresa A; Iqbal, Muzammil; Gunn, L Cary; Bailey, Ryan C.
Afiliación
  • Luchansky MS; Department of Chemistry, Institute for Genomic Biology, and Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, 600 South Mathews Avenue, Urbana, IL 61801, United States.
Biosens Bioelectron ; 26(4): 1283-91, 2010 Dec 15.
Article en En | MEDLINE | ID: mdl-20708399
ABSTRACT
Silicon photonic microring resonators have emerged as a sensitive and highly multiplexed platform for real-time biomolecule detection. Herein, we profile the evanescent decay of device sensitivity towards molecular binding as a function of distance from the microring surface. By growing multilayers of electrostatically bound polymers extending from the sensor surface, we are able to empirically determine that the evanescent field intensity is characterized by a 1/e response decay distance of 63 nm. We then applied this knowledge to study the growth of biomolecular assemblies consisting of alternating layers of biotinylated antibody and streptavidin, which follow a more complex growth pattern. Additionally, by monitoring the shift in microring resonance wavelength upon the deposition of a radioactively labeled protein, the mass sensitivity of the ring resonator platform was determined to be 14.7±6.7 [pg/mm(2)]/Δpm. By extrapolating to the instrument noise baseline, the mass/area limit of detection is found to be 1.5±0.7 pg/mm(2). Taking the small surface area of the microring sensor into consideration, this value corresponds to an absolute mass detection limit of 125 ag (i.e. 0.8 zmol of IgG), demonstrating the remarkable sensitivity of this promising label-free biomolecular sensing platform.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Técnicas Biosensibles Tipo de estudio: Diagnostic_studies / Evaluation_studies Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2010 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Técnicas Biosensibles Tipo de estudio: Diagnostic_studies / Evaluation_studies Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2010 Tipo del documento: Article País de afiliación: Estados Unidos