Large range and high resolution on-line displacement measurement system by combining double interferometres.
Xie, Fang; Li, Min; Song, Ding; Sun, Jinling; Zhang, Tao.
Afiliación
  • Xie F; Laboratory for Optical Information Science and Technology, Department of Physics, School of Science, Beijing Jiaotong University, Beijing 100044, China. fxie@bjtu.edu.cn
Opt Express ; 18(24): 24961-8, 2010 Nov 22.
Article en En | MEDLINE | ID: mdl-21164840
ABSTRACT
A stabilized interferometric displacement measurement system, which is suitable for on-line measurement and is endowed with large measurement range and high resolution, is proposed. The system is stabilized by a feedback loop which compensates the influences induced by the environmental disturbances and makes the system stabile enough for on-line measurement. Two different wavelengths are working simultaneously in the system. The measurement range which is determined by the synthetic-wavelength interferometric signal is expanded to the order of millimeter, while the measurement resolution which is determined by one of the single-wavelength interferometric signal is the order of sub-nanometer.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Opt Express Asunto de la revista: OFTALMOLOGIA Año: 2010 Tipo del documento: Article País de afiliación: China