Your browser doesn't support javascript.
loading
Dynamic optical studies in materials testing with spectral-domain polarization-sensitive optical coherence tomography.
Stifter, David; Leiss-Holzinger, Elisabeth; Major, Zoltan; Baumann, Bernhard; Pircher, Michael; Götzinger, Erich; Hitzenberger, Christoph K; Heise, Bettina.
Afiliación
  • Stifter D; Christian Doppler Laboratory for Microscopic and Spectroscopic Material Characterization, Center for Surface- and Nanoanalytics, Johannes Kepler University Linz, Altenbergerstrasse 69, 4040 Linz, Austria. david.stifter@jku.at
Opt Express ; 18(25): 25712-25, 2010 Dec 06.
Article en En | MEDLINE | ID: mdl-21164917
By combining dynamic mechanical testing with spectral-domain polarization-sensitive optical coherence tomography (SD-PS-OCT) performed at 1550 nm we are able to directly investigate for the first time changes within scattering technical materials during tensile and fracture tests. Spatially and temporally varying polarization patterns, due to defects and material inhomogeneities, were observed within bulk polymer samples and used to finally obtain--with the help of advanced image processing algorithms--quantitative maps of the evolving internal stress distribution. Furthermore, locally increased stress within fiber-reinforced composite materials was identified in situ with SD-PS-OCT to cause depolarizing sites of fiber-matrix debonding prior the onset of complete structural failure.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Refractometría / Algoritmos / Ensayo de Materiales / Interpretación de Imagen Asistida por Computador / Tomografía de Coherencia Óptica / Pruebas de Dureza Tipo de estudio: Diagnostic_studies Idioma: En Revista: Opt Express Asunto de la revista: OFTALMOLOGIA Año: 2010 Tipo del documento: Article País de afiliación: Austria Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Refractometría / Algoritmos / Ensayo de Materiales / Interpretación de Imagen Asistida por Computador / Tomografía de Coherencia Óptica / Pruebas de Dureza Tipo de estudio: Diagnostic_studies Idioma: En Revista: Opt Express Asunto de la revista: OFTALMOLOGIA Año: 2010 Tipo del documento: Article País de afiliación: Austria Pais de publicación: Estados Unidos