The use of cation exchange matrix separation coupled with ICP-MS to directly determine platinum group element (PGE) and other trace element emissions from passenger cars equipped with diesel particulate filters (DPF).
Anal Bioanal Chem
; 399(8): 2731-40, 2011 Mar.
Article
en En
| MEDLINE
| ID: mdl-21210274
Inductively coupled plasma-mass spectrometry coupled with cation exchange matrix separation has been optimised for the direct determination of platinum group element (PGE) and trace element emissions from a diesel engine car. After matrix separation method detection limits of 1.6 ng g(-1) for Pd, 0.4 ng g(-1) for Rh and 4.3 ng g(-1) for Pt were achieved, the method was validated against the certified reference material BCR 723, urban road dust. The test vehicle was fitted with new and aged catalytic converters with and without diesel particulate filters (DPF). Samples were collected after three consecutive New European Driving Cycle (NEDC) of the particulate and "soluble" phases using a home-made sampler optimised for trace element analysis. Emission factors for the PGEs ranged from 0.021 ng km(-1) for Rh to 70.5 ng km(-1) for Pt; when a DPF was fitted, the emission factors for the PGEs actually used in the catalysts dropped by up to 97% (for Pt). Trace element emission factors were found to drop by a maximum of 92% for Ni to a minimum of 18% for Y when a DPF was fitted; a new DPF was also found to cause a reduction of up to 86% in the emission of particulate matter.