Your browser doesn't support javascript.
loading
Quantifying cortical bone water in vivo by three-dimensional ultra-short echo-time MRI.
Rad, Hamidreza Saligheh; Lam, Shing Chun Benny; Magland, Jeremy F; Ong, Henry; Li, Cheng; Song, Hee Kwon; Love, James; Wehrli, Felix W.
Afiliación
  • Rad HS; Laboratory for Structural NMR Imaging, Department of Radiology, University of Pennsylvania School of Medicine, Philadelphia, PA, USA.
NMR Biomed ; 24(7): 855-64, 2011 Aug.
Article en En | MEDLINE | ID: mdl-21274960
ABSTRACT
Bone contains a significant fraction of water that is not detectable with ordinary Cartesian imaging sequences. The advent of ultra-short echo-time (UTE) methods has allowed the recovery of this submillisecond T(2)* water. In this work, we have developed a new three-dimensional hybrid-radial ultra-short echo-time (3D HRUTE) imaging technique based on slab selection by means of half-sinc pulses, variable-TE slice encoding and algorithms for quantification. The protocol consists of collecting two datasets differing in TR, from which T(1) is extracted, which is needed for quantification. Unlike T(2)*, which has been found to vary within a narrow range and does not require individual correction, T(1) is critically subject dependent (range, 100-350 ms). No soft-tissue suppression was used to preserve the signal-to-noise ratio of the short-T(2) bone water protons or to minimize the loss of relatively mobile water in large pores. Critical for quantification is correction for spatial variations in reception field and selection of the endosteal boundary for inclusion of pixels in the bone water calculation, because of the ruffled boundary stemming from trabecularization of the endosteal surface. The reproducibility, evaluated in 10 subjects covering the age range 30-80 years, yielded an average coefficient of variation of 4.2% and an intraclass correlation coefficient of 0.95, suggesting that a treatment effect on the order of 5% could be detected in as few as 10 subjects. Lastly, experiments in specimens by means of graded deuterium exchange showed that approximately 90% of the detected signal arises from water protons, whose relaxation rates (1/T(1) and 1/T(2)*) scale linearly with the isotopic volume fraction of light water after stepwise exchange with heavy water. The data thus show conclusively that the method quantifies water even though, in vivo, no distinction can be made between various fractions, such as collagen-bound vs pore-resident water.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Huesos / Imagen por Resonancia Magnética / Agua Tipo de estudio: Guideline Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: NMR Biomed Asunto de la revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR Año: 2011 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Huesos / Imagen por Resonancia Magnética / Agua Tipo de estudio: Guideline Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: NMR Biomed Asunto de la revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR Año: 2011 Tipo del documento: Article País de afiliación: Estados Unidos