Principles for the design and calibration of radiation protection dosemeters for operational and protection quantities for eye lens dosimetry.
Radiat Prot Dosimetry
; 144(1-4): 257-61, 2011 Mar.
Article
en En
| MEDLINE
| ID: mdl-21362692
The work package two of the ORAMED project--Collaborative Project (2008-2011) supported by the European Commission within its seventh Framework Programme--is devoted to the study of the eye lens dosimetry. A first approach is to implement the use of H(p)(3) by providing new sets of conversion coefficients and well suited calibration and type test procedures. This approach is presented in other papers in the proceedings of this conference. Taking into account that the eye lens is an organ close to the surface of the body, another approach would be to directly estimate the absorbed dose to the eye lens, D(lens,est) through a special calibration procedure although this quantity is not directly measurable. This paper is a methodological paper that tries to identify the critical aspects of a dosimetry in terms of D(lens).
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Protección Radiológica
/
Radiometría
/
Monitoreo de Radiación
/
Cristalino
Tipo de estudio:
Prognostic_studies
Límite:
Humans
Idioma:
En
Revista:
Radiat Prot Dosimetry
Año:
2011
Tipo del documento:
Article
País de afiliación:
Francia
Pais de publicación:
Reino Unido