Your browser doesn't support javascript.
loading
Long-term changes in airway-wall thickness on computed tomography in asthmatic patients.
Matsumoto, H; Niimi, A; Takemura, M; Ueda, T; Yamaguchi, M; Matsuoka, H; Jinnai, M; Takeda, T; Otsuka, K; Oguma, T; Handa, T; Hirai, T; Chin, K; Mishima, M.
Afiliación
  • Matsumoto H; Department of Respiratory Medicine, Graduate School of Medicine, Kyoto University, Kyoto, Japan. hmatsumo@kuhp.kyoto-u.ac.jp
Article en En | MEDLINE | ID: mdl-21462801
BACKGROUND: Effects of long-term treatment with inhaled corticosteroids (ICSs) on airway-wall thickness in patients with asthma remain unknown. OBJECTIVES: To determine whether airway-wall thickness consistently decreases after long-term ICS treatment, and to analyze factors contributing to long-term airway-wall changes in asthmatics. METHODS: A retrospective analysis of long-term changes in airway-wall thickness using computed tomography was performed in 14 patients with asthma. Wall area corrected by body surface area (WA/BSA) was examined at baseline, 12 weeks after the commencement of ICSs (second measurement), and at least 2 years (mean +/- SEM. 4.2 +/- 0.5) after the second measurement (third measurement). Mean +/- SEM changes in WA/BSA from the second to the third measurements were analyzed. RESULTS: The mean change in WA/BSA was not significant between the second and the third measurements (-0.27 +/- 0.59 mm2/m2/y). Overall, the changes were significantly associated with disease duration but not with other clinical indices. When the 14 patients were divided into 2 groups using a cutoff value of 0.32 mm2/m2/y for the mean change in WA/BSA, for the 5 patients whose WA/BSA exceeded this cutoff, daily ICS doses were not reduced and both forced expiratory volume in the first second (FEV1) and forced vital capacity decreased significantly. For the remaining 9 patients, daily ICS doses were reduced and long-term FEV1 values did not change. CONCLUSIONS: Despite long-term treatment with ICSs, airway-wall thickness did not consistently decrease. One possible mechanism underlying poor response to long-term treatment may be long-standing asthma.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Sistema Respiratorio / Asma / Tomografía Computarizada por Rayos X / Corticoesteroides Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Investig Allergol Clin Immunol Asunto de la revista: ALERGIA E IMUNOLOGIA Año: 2011 Tipo del documento: Article País de afiliación: Japón Pais de publicación: España
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Sistema Respiratorio / Asma / Tomografía Computarizada por Rayos X / Corticoesteroides Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Investig Allergol Clin Immunol Asunto de la revista: ALERGIA E IMUNOLOGIA Año: 2011 Tipo del documento: Article País de afiliación: Japón Pais de publicación: España