Your browser doesn't support javascript.
loading
Evaluating glycemic control algorithms by computer simulations.
Wilinska, Malgorzata E; Blaha, Jan; Chassin, Ludovic J; Cordingley, Jeremy J; Dormand, Natalie C; Ellmerer, Martin; Haluzik, Martin; Plank, Johannes; Vlasselaers, Dirk; Wouters, Pieter J; Hovorka, Roman.
Afiliación
  • Wilinska ME; Institute of Metabolic Science, University of Cambridge, Cambridge, United Kingdom. mew37@cam.ac.uk
Diabetes Technol Ther ; 13(7): 713-22, 2011 Jul.
Article en En | MEDLINE | ID: mdl-21488803
ABSTRACT

BACKGROUND:

Numerous guidelines and algorithms exist to achieve glycemic control. Their strengths and weaknesses are difficult to assess without head-to-head comparison in time-consuming clinical trials. We hypothesized that computer simulations may be useful.

METHODS:

Two open-label randomized clinical trials were replicated using computer simulations. One study compared performance of the enhanced model predictive control (eMPC) algorithm at two intensive care units in the United Kingdom and Belgium. The other study compared three glucose control algorithms-eMPC, Matias (the absolute glucose protocol), and Bath (the relative glucose change protocol)-in a single intensive care unit. Computer simulations utilized a virtual population of 56 critically ill subjects derived from routine data collected at four European surgical and medical intensive care units.

RESULTS:

In agreement with the first clinical study, computer simulations reproduced the main finding and discriminated between the two intensive care units in terms of the sampling interval (1.3 h vs. 1.8 h, United Kingdom vs. Belgium; P < 0.01). Other glucose control metrics were comparable between simulations and clinical results. The principal outcome of the second study was also reproduced. The eMPC demonstrated better performance compared with the Matias and Bath algorithms as assessed by the time when plasma glucose was in the target range between 4.4 and 6.1 mmol/L (65% vs. 43% vs. 42% [P < 0.001], eMPC vs. Matias vs. Bath) without increasing the risk of severe hypoglycemia.

CONCLUSIONS:

Computer simulations may provide resource-efficient means for preclinical evaluation of algorithms for glycemic control in the critically ill.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Algoritmos / Simulación por Computador / Enfermedad Crítica / Complicaciones de la Diabetes / Diabetes Mellitus / Hiperglucemia / Hipoglucemia Tipo de estudio: Etiology_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Diabetes Technol Ther Asunto de la revista: ENDOCRINOLOGIA / TERAPEUTICA Año: 2011 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Algoritmos / Simulación por Computador / Enfermedad Crítica / Complicaciones de la Diabetes / Diabetes Mellitus / Hiperglucemia / Hipoglucemia Tipo de estudio: Etiology_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Diabetes Technol Ther Asunto de la revista: ENDOCRINOLOGIA / TERAPEUTICA Año: 2011 Tipo del documento: Article País de afiliación: Reino Unido