Elevated Endotoxin Levels in Human Intravenous Immunoglobulin Concentrates Caused by (1->3)-{beta}-D-Glucans.
PDA J Pharm Sci Technol
; 64(6): 536-44, 2010.
Article
en En
| MEDLINE
| ID: mdl-21502064
Endotoxins have been measured routinely in the final product and during the production process to produce non-pyrogenic parenterals. Limulus-amoebocyte-lysate-reactive material was found in in-process samples and final product of one of Octapharma's intravenous immunoglobulin (IVIG) preparations. Limulus-amoebocyte-lysate (LAL) is activated by bacterial endotoxins and by (1â3)-ß-D-glucans. The contribution of both compounds on the LAL-related signal was determined by three different approaches: (1) using a test specific for (1â3)-ß-D-glucans, (2) by addition of ß-glucan blocker, and (3) by the use of a recombinant endotoxin assay. It was shown that none of our IVIG concentrates contained elevated endotoxin contents but that the higher LAL reaction could be ascribed to (1â3)-ß-D-glucans extracted from cellulose filter pads. The use of an endotoxin test kit highly sensitive for (1â3)-ß-D-glucans might lead to false-positive results. (1â3)-ß-D-glucans spike solutions did not evoke an increase of temperature in rabbits, suggesting that a pyrogenic reaction is not expected in patients. LAY ABSTRACT: Endotoxins have been measured routinely in the final product and during the production process to produce non-pyrogenic parenterals. Limulus-amoebocyte-lysate-reactive material was found in in-process samples and final product of one of Octapharma's intravenous immunoglobulin (IVIG) preparations. Limulus-amoebocyte-lysate (LAL) is activated by bacterial endotoxins and by (1â3)-ß-D-glucans. The contribution of both compounds on the LAL-related signal was determined by three different approaches: (1) using a test specific for (1â3)-ß-D-glucans, (2) by addition of ß-glucan blocker, and (3) by the use of a recombinant endotoxin assay. It has been shown that none of our IVIG concentrates contained elevated endotoxin contents but that the higher LAL reaction could be ascribed to (1â3)-ß-D-glucans extracted from cellulose filter pads. The use of an endotoxin test kit highly sensitive for (1â3)-ß-D-glucans might lead to false-positive results. (1â3)-ß-D-glucans spike solutions did not evoke an increase of temperature in rabbits suggesting that a pyrogenic reaction is not expected in patients.
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Glucanos
/
Prueba de Limulus
Límite:
Animals
/
Humans
Idioma:
En
Revista:
PDA J Pharm Sci Technol
Asunto de la revista:
FARMACIA
/
FARMACOLOGIA
Año:
2010
Tipo del documento:
Article
País de afiliación:
Austria
Pais de publicación:
Estados Unidos