Your browser doesn't support javascript.
loading
Determination of unbound vismodegib (GDC-0449) concentration in human plasma using rapid equilibrium dialysis followed by solid phase extraction and high-performance liquid chromatography coupled to mass spectrometry.
Deng, Yuzhong; Wong, Harvey; Graham, Richard A; Liu, Wenbin; Shen, Heuy-shin; Shi, Yao; Wang, Laixin; Meng, Min; Malhi, Vikram; Ding, Xiao; Dean, Brian.
Afiliación
  • Deng Y; Drug Metabolism and Pharmacokinetics, Genentech, South San Francisco, CA 94080, USA. yuzhongd@gene.com
J Chromatogr B Analyt Technol Biomed Life Sci ; 879(22): 2119-26, 2011 Jul 15.
Article en En | MEDLINE | ID: mdl-21704573
A rapid equilibrium dialysis (RED) assay followed by a solid phase extraction (SPE) high-performance liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for the quantitative determination of unbound vismodegib in human plasma was developed and validated. The equilibrium dialysis was carried out using 0.3 mL plasma samples in the single-use plate RED system at 37°C for 6h. The dialysis samples (0.1 mL) were extracted using a Strata-X-C 33u Polymeric Strong Cation SPE plate and the resulting extracts were analyzed using reverse-phase chromatography and positive electrospray ionization (ESI) mass spectrometry. The standard curve, which ranged from 0.100 to 100 ng/mL for vismodegib, was fitted to a 1/x(2) weighted linear regression model. The lower limit of quantitation (LLOQ, 0.100 ng/mL) was sufficient to quantify unbound concentrations of vismodegib after dialysis. The intra-assay precision of the LC-MS/MS assay, based on the four analytical QC levels (LLOQ, low, medium and high), was within 7.7% CV and inter-assay precision was within 5.5% CV. The assay accuracy, expressed as %Bias, was within ±4.0% of the nominal concentration values. Extraction recovery of vismodegib was between 77.9 and 84.0%. The assay provides a means for accurate assessment of unbound vismodegib plasma concentrations in clinical studies.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Piridinas / Cromatografía Líquida de Alta Presión / Diálisis / Espectrometría de Masas en Tándem / Extracción en Fase Sólida / Anilidas Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Female / Humans / Male Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2011 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Piridinas / Cromatografía Líquida de Alta Presión / Diálisis / Espectrometría de Masas en Tándem / Extracción en Fase Sólida / Anilidas Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Female / Humans / Male Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2011 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Países Bajos