Your browser doesn't support javascript.
loading
Molecular imaging with optical coherence tomography using ligand-conjugated microparticles that detect activated endothelial cells: rational design through target quantification.
Jefferson, Andrew; Wijesurendra, Rohan S; McAteer, Martina A; Digby, Janet E; Douglas, Gillian; Bannister, Thomas; Perez-Balderas, Francisco; Bagi, Zsolt; Lindsay, Alistair C; Choudhury, Robin P.
Afiliación
  • Jefferson A; Department of Cardiovascular Medicine and Oxford Acute Vascular Imaging Centre, University of Oxford, John Radcliffe Hospital, Oxford OX3 9DU, United Kingdom.
Atherosclerosis ; 219(2): 579-87, 2011 Dec.
Article en En | MEDLINE | ID: mdl-21872249
ABSTRACT

OBJECTIVES:

Optical coherence tomography (OCT) is a high resolution imaging technique used to assess superficial atherosclerotic plaque morphology. Utility of OCT may be enhanced by contrast agents targeting molecular mediators of inflammation. METHODS AND

RESULTS:

Microparticles of iron oxide (MPIO; 1 and 4.5 µm diameter) in suspension were visualized and accurately quantified using a clinical optical coherence tomography system. Bound to PECAM-1 on a plane of cultured endothelial cells under static conditions, 1 µm MPIO were also readily detected by OCT. To design a molecular contrast probe that would bind activated endothelium under conditions of shear stress, we quantified the expression (basal vs. TNF-activated; molecules µm(-2)) of VCAM-1 (not detected vs. 16 ± 1); PECAM-1 (132 ± 6 vs. 198 ± 10) and E-selectin (not detected vs. 46 ± 0.6) using quantitative flow cytometry. We then compared the retention of antibody-conjugated MPIO targeting each of these molecules plus a combined VCAM-1 and E-selectin (E+V) probe across a range of physiologically relevant shear stresses. E+V MPIO were consistently retained with highest efficiency (P < 0.001) and at a density that provided conspicuous contrast effects on OCT pullback.

CONCLUSION:

Microparticles of iron oxide were detectable using a clinical OCT system. Assessment of binding under flow conditions recommended an approach that targeted both E-selectin and VCAM-1. Bound to HUVEC under conditions of flow, targeted 1 µm E+V MPIO were readily identified on OCT pullback. Molecular imaging with OCT may be feasible in vivo using antibody targeted MPIO.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Compuestos Férricos / Sondas Moleculares / Vasos Coronarios / Tomografía de Coherencia Óptica / Imagen Molecular / Células Endoteliales de la Vena Umbilical Humana Tipo de estudio: Prognostic_studies Límite: Animals / Humans / Male Idioma: En Revista: Atherosclerosis Año: 2011 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Compuestos Férricos / Sondas Moleculares / Vasos Coronarios / Tomografía de Coherencia Óptica / Imagen Molecular / Células Endoteliales de la Vena Umbilical Humana Tipo de estudio: Prognostic_studies Límite: Animals / Humans / Male Idioma: En Revista: Atherosclerosis Año: 2011 Tipo del documento: Article País de afiliación: Reino Unido