Your browser doesn't support javascript.
loading
Biodistribution and radiation dosimetry of the serotonin 5-HT6 ligand [¹¹C]GSK215083 determined from human whole-body PET.
Comley, Robert A; Salinas, Cristian; Mizrahi, Romina; Vitcu, Irina; Ng, Alvina; Hallett, William; Keat, Nicholas; Wilson, Alan A; Rabiner, Eugenii A; Laruelle, Marc; Houle, Sylvain.
Afiliación
  • Comley RA; GlaxoSmithKline Clinical Imaging Centre, Imperial College London, Hammersmith Hospital, Du Cane Road, London, W12 0NN, UK.
Mol Imaging Biol ; 14(4): 517-21, 2012 Aug.
Article en En | MEDLINE | ID: mdl-22076076
ABSTRACT

PURPOSE:

We measured the whole-body distribution of IV-injected [¹¹C]GSK215083, a new 5-HT6 antagonist PET tracer, as a function of time in adult subjects, in order to determine the radiation exposure. PROCEDURES After injection with a single bolus of [¹¹C]GSK215083 (range 330-367 MBq; mean 346 MBq), PET emission data were acquired for approximately 120 min in six subjects (three males and three females). Five organs were identified as exhibiting uptake above background. For these, regions of interest were delineated on emission images, and time-activity curves (TAC) generated. Residence times were calculated as the area under the curve of the TAC, normalized to injected activities and standard values of organ volumes. Dosimetry calculations were then performed using the computer program OLINDA/EXM 1.0.

RESULTS:

The mean effective dose averaged over both males and females (deviation) was estimated to be 7.7 ± 1.0 µSv/MBq (male 7.0 ± 0.4; female 8.5 ± 0.6). For the effective dose equivalent, the corresponding values are 7.8 ± 1.2 µSv/MBq (male 6.8 ± 0.5; female 8.9 ± 0.1). The organ receiving the highest dose was the lung, with an average equivalent dose of 25.6 ± 6.9 µSv/MBq (male 20.8 ± 5.6; female 30.4 ± 4.4).

CONCLUSION:

The estimated radiation dose for [¹¹C]GSK215083 is consistent with those for other neuroreceptor ligands labeled with carbon-11. The somewhat higher dose estimate for females compared to males may reflect the difference in observed residence times and representative differences in the male and female phantoms used for dosimetry calculations. Based on conventionally accepted dose limits, [¹¹C]GSK215083 may be used for multiple PET scans in the same subject.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Quinolinas / Radiometría / Sulfonas / Receptores de Serotonina / Tomografía de Emisión de Positrones / Imagen de Cuerpo Entero Tipo de estudio: Prognostic_studies Límite: Adolescent / Adult / Female / Humans / Male Idioma: En Revista: Mol Imaging Biol Asunto de la revista: BIOLOGIA MOLECULAR / DIAGNOSTICO POR IMAGEM Año: 2012 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Quinolinas / Radiometría / Sulfonas / Receptores de Serotonina / Tomografía de Emisión de Positrones / Imagen de Cuerpo Entero Tipo de estudio: Prognostic_studies Límite: Adolescent / Adult / Female / Humans / Male Idioma: En Revista: Mol Imaging Biol Asunto de la revista: BIOLOGIA MOLECULAR / DIAGNOSTICO POR IMAGEM Año: 2012 Tipo del documento: Article País de afiliación: Reino Unido