OBJECTIVES: Emergency medicine is increasingly recognized as a medical specialty in Japan. However, comprehensive studies evaluating emergency airway management practice are lacking. We describe emergency department (ED) airway management using a large multi-center registry. METHODS: We formed the Japanese Emergency Airway Network, a consortium of 10 academic and community medical centers in Japan, and prospectively collected data on ED intubations from April 2010 to February 2011. All patients undergoing emergency intubation were eligible for inclusion. Data were entered in real time by the intubator using a standardized data form. Variables included patient's age, sex, weight, indication for intubation, methods of intubation, drugs, level of training and specialty of the intubator, number of attempts, success or failure, and adverse events. We present descriptive data as proportions with 95% confidence intervals. RESULTS: We recorded 1486 intubations (compliance rate 99%). Intubation was ultimately successful in 99.7%. The initial method of intubation varied substantially among the hospitals, including rapid sequence intubation (0-79%), sedation without paralysis (4-88%), paralysis without sedation (0-18%), and oral without medication (12-67%), in non-cardiac arrest encounters. Success rates in first and ≤3 attempts ranged from 40 to 83% and from 74 to 100%, respectively. The overall adverse event rate was 11%, without significant difference by the method used. CONCLUSIONS: In this multi-center study characterizing ED airway management across Japan, we observed a high overall success rate but a high degree of variation among hospitals in the methods of intubation and success rates.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Gestión de la Calidad Total / Administración de la Seguridad / Obstrucción de las Vías Aéreas / Intubación Intratraqueal Tipo de estudio: Clinical_trials / Etiology_studies / Evaluation_studies / Observational_studies / Risk_factors_studies Límite: Female / Humans / Male País/Región como asunto: Asia Idioma: En Revista: Resuscitation Año: 2012 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Irlanda

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Gestión de la Calidad Total / Administración de la Seguridad / Obstrucción de las Vías Aéreas / Intubación Intratraqueal Tipo de estudio: Clinical_trials / Etiology_studies / Evaluation_studies / Observational_studies / Risk_factors_studies Límite: Female / Humans / Male País/Región como asunto: Asia Idioma: En Revista: Resuscitation Año: 2012 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Irlanda