Second-generation annealed highly cross-linked polyethylene exhibits low wear.
D'Antonio, James A; Capello, William N; Ramakrishnan, Rama.
Afiliación
  • D'Antonio JA; Sewickley Valley Hospital Sewickley, PA, USA. dantonioja@me.com
Clin Orthop Relat Res ; 470(6): 1696-704, 2012 Jun.
Article en En | MEDLINE | ID: mdl-22161120
ABSTRACT

BACKGROUND:

Compared with conventional polyethylene, first-generation highly cross-linked polyethylenes have low wear, but controversy exists regarding their reduced mechanical strength and/or retained free radicals. Second-generation highly cross-linked polyethylenes have been developed to reduce wear, maintain mechanical strength, and have oxidative resistance, but it is unclear whether they do so. QUESTIONS/

PURPOSES:

The primary objective of this study therefore was to determine if a second-generation annealed material has low linear wear at 5 years followup. Secondary objectives were to evaluate for overall survivorship, implant fixation, osteolysis, and effect of socket inclination on wear.

METHODS:

In a multicenter prospective study, we radiographically evaluated 155 patients (167 hips) at 3 years, 124 patients (132 hips) at 4 years, and 46 patients (51 hips) at 5 years. The linear head penetration rate was measured at 6 weeks, 1 year, and yearly through 5 years.

RESULTS:

The head penetration per year after the first year of bedding-in was 0.024 mm per year at 3 years, 0.020 mm per year at 4 years, and 0.008 mm per year at 5 years. The average wear rate over 5 years was 0.015 mm per year and represents a 58% improvement over a first-generation annealed highly cross-linked polyethylene. The Kaplan-Meier survivorship (revision for any reason) was 97.8%. We revised no hip for bearing surface failure and observed no osteolysis. Socket inclination did not affect linear wear.

CONCLUSIONS:

These data suggest the linear wear rate for a second-generation annealed highly cross-linked polyethylene is no greater than that for historic controls of first-generation highly cross-linked polyethylenes, and no untoward complications were encountered with this new material. LEVEL OF EVIDENCE Level II, prognostic study. See the Guidelines for Authors for a complete description of levels of evidence.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Falla de Prótesis / Artroplastia de Reemplazo de Cadera / Polietileno / Prótesis de Cadera Tipo de estudio: Clinical_trials / Diagnostic_studies / Observational_studies / Prognostic_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Orthop Relat Res Año: 2012 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Falla de Prótesis / Artroplastia de Reemplazo de Cadera / Polietileno / Prótesis de Cadera Tipo de estudio: Clinical_trials / Diagnostic_studies / Observational_studies / Prognostic_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Orthop Relat Res Año: 2012 Tipo del documento: Article País de afiliación: Estados Unidos