Intraocular lens power calculation for humanitarian missions based on partial biometry.
J Cataract Refract Surg
; 38(7): 1187-91, 2012 Jul.
Article
en En
| MEDLINE
| ID: mdl-22608028
PURPOSE: To determine whether the correlation between corneal power (K) and axial length (AL) can be used for intraocular lens (IOL) power calculation when biometric data are incomplete. SETTING: Developing regions served by United States Navy humanitarian assistance missions. DESIGN: Case series. METHODS: Measurements of K and AL were collected from all adult cataract surgery charts and used to calculate emmetropic IOL powers. A formula for estimating K or AL was derived by Deming regression analysis. The emmetropic IOL powers were calculated by hypothetical scenarios as follows: (1) K estimated from the formula and measured AL, (2) mean population K and measured AL, (3) measured K and estimated AL, and (4) measured K and mean population AL. The mean absolute refractive error (MAE) was calculated for each hypothetical scenario and an additional scenario (scenario 5) using single IOL power for all eyes. The MAEs were compared with a paired t test. RESULTS: The formula derived from Deming regression analysis was K = 74.56 - 1.317 × AL. The MAE for the scenarios were (1) 0.90 diopters (D), (2) 1.11 D, (3) 1.91 D, (4) 1.55 D, and (5) 1.22 D. The MAE for scenario 1 was significantly less (P<.01) than that for scenarios 2 and 5. The MAE for scenario 5 was significantly less than that for scenarios 3 and 4. CONCLUSIONS: The correlation between K and AL can be used to improve accuracy of IOL calculation when K is unavailable. When the AL is unavailable, the mean population IOL power is most accurate. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Biometría
/
Altruismo
/
Óptica y Fotónica
/
Lentes Intraoculares
/
Misiones Médicas
Tipo de estudio:
Observational_studies
Límite:
Adult
/
Humans
Idioma:
En
Revista:
J Cataract Refract Surg
Asunto de la revista:
OFTALMOLOGIA
Año:
2012
Tipo del documento:
Article
País de afiliación:
Estados Unidos
Pais de publicación:
Estados Unidos