Your browser doesn't support javascript.
loading
Biochemical dynamics relevant to the safety of low-dose, intraclot alteplase for deep vein thrombosis.
Lozier, Jay N; Cullinane, Ann M; Nghiem, Khanh; Chang, Richard; Horne, McDonald K.
Afiliación
  • Lozier JN; Department of Laboratory Medicine, National Institutes of Health Clinical Center, Bethesda, MD, USA. lozierjn@cc.nih.gov
Transl Res ; 160(3): 217-22, 2012 Sep.
Article en En | MEDLINE | ID: mdl-22683421
ABSTRACT
Intraclot tissue plasminogen activator (tPA) has been shown to be an effective treatment for deep vein thrombosis (DVT) (Radiology 2008;246619 and J Vasc Interv Radiol 2011;221107). We sought to correlate pharmacokinetics of tPA, fibrinogen, fibrinolytic inhibitors, and D-dimers with the safety and efficacy of intraclot tPA. Thirty subjects received intraclot tPA for lower extremity DVT by infiltrating the thrombus with ≤10 mg doses tPA in an open-label study, using a pulse-spray catheter. We measured various parameters over 8 h following a first dose of tPA. Mean tPA levels of 75 units per mL (95% confidence interval 19-131 units/mL) were seen immediately after administration of a mean tPA dose of 8.0 mg (SD 1.5 mg). tPA levels returned to baseline within 2 h of completion of treatment. Plasminogen activator inhibitor-1 (PAI-1) was consumed following tPA treatment, but rose to levels significantly greater than baseline (P < 0.001). Fibrinogen decreased slightly, but remained >125 mg/dL for all subjects. α2-antiplasmin decreased from a mean of 115 units/mL to 56 units/mL after tPA administration (P < 0.001) and remained decreased for 8 h. Plasminogen at baseline (112 units/mL) decreased to 89 units/mL immediately after tPA administration (P < 0.001) and was unchanged thereafter. D-dimer levels were >20 µg/mL in all but 4 subjects, one of whom was the only one to fail to achieve clot lysis. The safety of low-dose, intraclot tPA is due to its short persistence in the circulation, lack of hypofibrinogenemia, and a reflexive rise of PAI-1. Subjects whose D-dimers remain <20 µg/mL are at risk of not achieving thrombolysis.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Activador de Tejido Plasminógeno / Trombosis de la Vena / Fibrinolíticos Límite: Humans Idioma: En Revista: Transl Res Asunto de la revista: MEDICINA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Año: 2012 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Activador de Tejido Plasminógeno / Trombosis de la Vena / Fibrinolíticos Límite: Humans Idioma: En Revista: Transl Res Asunto de la revista: MEDICINA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Año: 2012 Tipo del documento: Article País de afiliación: Estados Unidos