In this study, we compared the sealing characteristics and efficacy of a fibrin sealant with reduced plasminogen (FS-rplg) and a fibrin sealant with aprotinin as a fibrinolysis inhibitor (FS-apr). The relevant sealing characteristics including clot structure, fibrin chain cross-linking, and clot lysis were tested in the laboratory. The sealing efficacy was then investigated in a follow-up animal model to determine differences in the in vivo sealing properties. A total of 46 animals were available for the final analysis with 23 animals in each treatment arm. In conclusion, we saw differences in vitro between FS-rplg and FS-apr in ultrastructure and α-chain cross-linking rates as well as in the rate of fibrinolysis. These differences may explain the significantly enhanced sealing efficacy in FS-apr compared to FS-rplg shown in vivo in a rabbit intestinal model.