Near-infrared spectroscopy of the thenar eminence: comparison of dynamic testing protocols.
Lipcsey, Miklós; Eastwood, Glenn M; Woinarski, Nicholas C Z; Bellomo, Rinaldo.
Afiliación
  • Lipcsey M; Department of Surgery, Section of Anaesthesiology and Intensive Care, Uppsala University, Uppsala, Sweden.
Crit Care Resusc ; 14(2): 142-7, 2012 Jun.
Article en En | MEDLINE | ID: mdl-22697622
BACKGROUND: Near-infrared spectroscopy of the thenar eminence (NIRSth) is a non-invasive bedside method for assessing tissue oxygenation. The vascular occlusion test (VOT) with a pressure cuff can be used to provide a dynamic assessment of the tissue oxygenation response to ischaemia. VOT has been applied to assess the microcirculation by NIRSth in critically ill patients. The optimal mode of performing such VOT, however, remains controversial. DESIGN, PARTICIPANTS AND SETTING: Prospective observational study among a cohort of 11 healthy volunteers in a tertiary intensive care department. INTERVENTION: Measurement of NIRS-derived parameters using 1-, 2- and 3-minute VOTs or VOT to 40% tissue oxygen saturation (StO(2)). MAIN OUTCOME MEASURE: Changes in StO(2) and tissue haemoglobin index (THI) over time, and relative change from baseline for StO(2) and THI. RESULTS: Mean baseline StO(2) was 80% (SD, 5%) and mean THI was 13.7 (SD, 1.9). The lowest StO(2) at the end of the VOT was 39% (SD, 13%) and 39% (SD, 2%) in the 3- minute and the 40% StO(2) VOTs, respectively. The duration of the 40% StO(2) VOT ranged from 1:35 to 8:21 minutes (median, 3:29 min). There was a difference between the StO(2) curves for the 3-minute and 40% StO(2) VOT (P = 0.005) but not the THI curves. Reported pain score was a median of 3.5 (IQR, 2.5-5.5) and 4 (IQR 2-4) for the 3-minute and 40% StO(2) VOTs, respectively. CONCLUSIONS: The 3-minute VOT and the 40% StO(2) appear equivalent. However, the 3-minute VOT carries a degree of decreased patient discomfort and shorter overall duration of execution.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Consumo de Oxígeno / Sistemas de Atención de Punto / Espectroscopía Infrarroja Corta / Mano / Isquemia Tipo de estudio: Etiology_studies / Incidence_studies / Observational_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Crit Care Resusc Asunto de la revista: TERAPIA INTENSIVA Año: 2012 Tipo del documento: Article País de afiliación: Suecia Pais de publicación: Países Bajos
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Consumo de Oxígeno / Sistemas de Atención de Punto / Espectroscopía Infrarroja Corta / Mano / Isquemia Tipo de estudio: Etiology_studies / Incidence_studies / Observational_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Crit Care Resusc Asunto de la revista: TERAPIA INTENSIVA Año: 2012 Tipo del documento: Article País de afiliación: Suecia Pais de publicación: Países Bajos