Your browser doesn't support javascript.
loading
Homogeneous duplex polymerase chain reaction assay using switchable lanthanide fluorescence probes.
Lehmusvuori, Ari; Tapio, Antti-Heikki; Mäki-Teeri, Petra; Rantakokko-Jalava, Kaisu; Wang, Qi; Takalo, Harri; Soukka, Tero.
Afiliación
  • Lehmusvuori A; Department of Biochemistry and Food Chemistry, Division of Biotechnology, University of Turku, 20520 Turku, Finland. ari.lehmusvuori@utu.fi
Anal Biochem ; 436(1): 16-21, 2013 May 01.
Article en En | MEDLINE | ID: mdl-23353013
ABSTRACT
We have developed a duplex polymerase chain reaction (PCR) assay based on switchable lanthanide chelate complementation probes. In the complementation probe technology, two nonfluorescent oligonucleotide probes, one labeled with a lanthanide ion carrier chelate and another with a light absorbing antenna ligand, form a fluorescent complex by self-assembly of the reporter molecules when the two probes are hybridized in adjacent positions to the target DNA. Here we report the synthesis of a new terbium(III) (Tb(III)) ion carrier chelate and a new light-absorbing antenna ligand for Tb(III) and the development of a duplex Chlamydia trachomatis (Ct) PCR assay. For the detection of Ct in urine samples, a specific sequence in Ct cryptic plasmid was amplified and detected using europium(III) (Eu(III)) complementation probes. An internal amplification control was amplified in each reaction and detected using Tb(III) complementation probes to verify the Ct negative results. Ct bacteria were concentrated from urine samples with a rapid and simple centrifugation-based sample preparation method. Good diagnostic accuracy (99-100%) was achieved, and also Ct positive reactions yielded a very high Eu(III) signal-to-background ratio (maximum of 244). High performance of the complementation probes is advantageous when sample may contain impurities after a simple sample preparation.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Terbio / Sondas de Oligonucleótidos / Infecciones por Chlamydia / Chlamydia trachomatis / Reacción en Cadena en Tiempo Real de la Polimerasa / Colorantes Fluorescentes Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Anal Biochem Año: 2013 Tipo del documento: Article País de afiliación: Finlandia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Terbio / Sondas de Oligonucleótidos / Infecciones por Chlamydia / Chlamydia trachomatis / Reacción en Cadena en Tiempo Real de la Polimerasa / Colorantes Fluorescentes Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Anal Biochem Año: 2013 Tipo del documento: Article País de afiliación: Finlandia
...