Your browser doesn't support javascript.
loading
Fabrication of Cr doped SnO2 nanoparticles based biosensor for the selective determination of riboflavin in pharmaceuticals.
Lavanya, N; Radhakrishnan, S; Sekar, C; Navaneethan, M; Hayakawa, Y.
Afiliación
  • Lavanya N; Department of Bioelectronics and Biosensors, Alagappa University, Karaikudi-630003, Tamilnadu, India.
Analyst ; 138(7): 2061-7, 2013 Apr 07.
Article en En | MEDLINE | ID: mdl-23397580
We report the fabrication and testing of a riboflavin (RF) biosensor based on the use of Cr doped SnO2 nanoparticles. The Cr-SnO2 nanoparticles with chromium concentration from 0 to 5 wt% were synthesised by a microwave irradiation method. Magnetic studies revealed that only 3 wt% Cr doped nano-SnO2 has ferromagnetic behaviour at room temperature. This Cr-SnO2 nanoparticles modified electrode responded to RF linearly over a concentration range of 0.2 × 10(-6) to 1.0 × 10(-4) M with a detection limit of 107 nM. The fabricated sensor showed an excellent anti-interference ability against electroactive species and metal ions and proved to be useful for the estimation of the RF content in pharmaceutical samples with satisfactory recovery.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Riboflavina / Preparaciones Farmacéuticas / Técnicas Biosensibles / Cromo / Compuestos de Estaño / Nanopartículas del Metal Idioma: En Revista: Analyst Año: 2013 Tipo del documento: Article País de afiliación: India Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Riboflavina / Preparaciones Farmacéuticas / Técnicas Biosensibles / Cromo / Compuestos de Estaño / Nanopartículas del Metal Idioma: En Revista: Analyst Año: 2013 Tipo del documento: Article País de afiliación: India Pais de publicación: Reino Unido