Experimentally and computationally fast method for estimation of a mean kurtosis.
Magn Reson Med
; 69(6): 1754-60, 2013 Jun.
Article
en En
| MEDLINE
| ID: mdl-23589312
PURPOSE: Results from several recent studies suggest the magnetic resonance diffusion-derived metric mean kurtosis (MK) to be a sensitive marker for tissue pathology; however, lengthy acquisition and postprocessing time hamper further exploration. The purpose of this study is to introduce and evaluate a new MK metric and a rapid protocol for its estimation. METHODS: The protocol requires acquisition of 13 standard diffusion-weighted images, followed by linear combination of log diffusion signals, thus avoiding nonlinear optimization. The method was evaluated on an ex vivo rat brain and an in vivo human brain. Parameter maps were compared with MK estimated from a standard diffusion kurtosis imaging (DKI) data set comprising 160 diffusion-weighted images. RESULTS: The new MK displays remarkably similar contrast to MK, and the proposed protocol acquires the necessary data in less than 1 min for full human brain coverage, with a postprocessing time of a few seconds. Scan-rescan reproducibility was comparable with MK. CONCLUSION: The framework offers a robust and rapid method for estimating MK, with a protocol easily adapted on commercial scanners, as it requires only minimal modification of standard diffusion-weighting protocols. These properties make the method feasible in practically any clinical setting.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Algoritmos
/
Encéfalo
/
Imagen por Resonancia Magnética
/
Interpretación de Imagen Asistida por Computador
/
Aumento de la Imagen
Tipo de estudio:
Diagnostic_studies
/
Guideline
Límite:
Humans
Idioma:
En
Revista:
Magn Reson Med
Asunto de la revista:
DIAGNOSTICO POR IMAGEM
Año:
2013
Tipo del documento:
Article
País de afiliación:
Dinamarca
Pais de publicación:
Estados Unidos