Your browser doesn't support javascript.
loading
Fast and simultaneous analysis of biothiols by high-performance liquid chromatography with fluorescence detection under hydrophilic interaction chromatography conditions.
Isokawa, Muneki; Funatsu, Takashi; Tsunoda, Makoto.
Afiliación
  • Isokawa M; Graduate School of Pharmaceutical Sciences, University of Tokyo, 7-3-1 Hongo, Tokyo 113-0033, Japan.
Analyst ; 138(13): 3802-8, 2013 Jul 07.
Article en En | MEDLINE | ID: mdl-23702918
ABSTRACT
A method for analyzing biothiols based on high-performance liquid chromatography (HPLC)-fluorescence detection under hydrophilic interaction chromatography (HILIC) conditions has been developed. Thiols were derivatized with nonfluorescent ammonium 7-fluoro-2,1,3-benzoxadiazole-4-sulfonate (SBD-F), which selectively reacts with the thiol groups to furnish the corresponding fluorescent SBD-thiols. Among the six different kinds of HILIC columns examined, the ZIC-HILIC column with sulfobetaine groups in the stationary phase proved to be the best for the separation of SBD-thiols. Eight thiols-N-acetylcysteine, cysteamine, homocysteine, cysteine, cysteinylglycine, glutathione, γ-glutamylcysteine, and internal standard N-(2-mercaptopropionyl)glycine-were baseline-separated within 10 min. The detection sensitivity was improved partly due to the increase in the SBD-thiol fluorescence owing to the acetonitrile-rich mobile phase used. The detection limits at a signal-to-noise ratio of 3 were 0.02-3.4 nmol l(-1). The method could successfully quantify six thiols in a human plasma sample, while cysteamine could not be detected. Both the intra- and interday precisions were below 4% for homocysteine, cysteine, cysteinylglycine, glutathione, and γ-glutamylcysteine except for N-acetylcysteine. This method should be a useful tool for investigating the relationship between sulfur metabolism and related diseases, since a multicomponent system consisting of different thiol compounds could be analyzed simultaneously with high sensitivity within a short time.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Compuestos de Sulfhidrilo / Cromatografía Líquida de Alta Presión / Interacciones Hidrofóbicas e Hidrofílicas Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Analyst Año: 2013 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Compuestos de Sulfhidrilo / Cromatografía Líquida de Alta Presión / Interacciones Hidrofóbicas e Hidrofílicas Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Analyst Año: 2013 Tipo del documento: Article País de afiliación: Japón