Temperature and curing time affect composite sorption and solubility.
Castro, Fabrício Luscino Alves de; Campos, Bruno Barbosa; Bruno, Kely Firmino; Reges, Rogério Vieira.
Afiliación
  • Castro FL; Dental Materials and Operative Dentistry, Paulista University, Goiânia, GO, Brazil. fabriciocastro.odontogo@unip.br
J Appl Oral Sci ; 21(2): 157-62, 2013.
Article en En | MEDLINE | ID: mdl-23739853
ABSTRACT

OBJECTIVE:

This study evaluated the effect of temperature and curing time on composite sorption and solubility. MATERIAL AND

METHODS:

Seventy five specimens (8×2 mm) were prepared using a commercial composite resin (ICE, SDI). Three temperatures (10°C, 25°C and 60°C) and five curing times (5 s, 10 s, 20 s, 40 s and 60 s) were evaluated. The specimens were weighed on an analytical balance three times A before storage (M1); B 7 days after storage (M2); C 7 days after storage plus 1 day of drying (M3). The storage solution consisted of 75% alcohol/25% water. Sorption and solubility were calculated using these three weights and specimen dimensions. The data were analyzed using the Kruskal-Wallis and Mann-Whitney U Tests (α=5%).

RESULTS:

The results showed that time, temperature and their interaction influenced the sorption and solubility of the composite (p<0.05). At 60°C, the composite sorption showed an inverse relationship with the curing time (p<0.05). The composite cured for 5 s showed higher sorption for the 40 s or 60 s curing times when compared with all temperatures (p<0.05). Curing times of 20 s and 40 s showed similar sorption data for all temperatures (p>0.05). The 60°C composite temperature led to lower values of sorption for all curing times when compared with the 10°C temperature (p<0.05). The same results were found when comparing 10°C and 25°C (p<0.05), except that the 20 s and 40 s curing times behaved similarly (p>0.05). Solubility was similar at 40 s and 60 s for all temperatures (p>0.05), but was higher at 10°C than at 60°C for all curing times (p<0.05). When the composite was cured at 25°C, similar solubility values were found when comparing the 5 s and 10 s or 20 s and 40 s curing times (p>0.05).

CONCLUSION:

In conclusion, higher temperatures or longer curing times led to lower sorption and solubility values for the composite tested; however, this trend was only significant in specific combinations of temperature and curing times.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Resinas Compuestas / Luces de Curación Dental / Polimerizacion Tipo de estudio: Evaluation_studies Idioma: En Revista: J Appl Oral Sci Asunto de la revista: ODONTOLOGIA Año: 2013 Tipo del documento: Article País de afiliación: Brasil

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Resinas Compuestas / Luces de Curación Dental / Polimerizacion Tipo de estudio: Evaluation_studies Idioma: En Revista: J Appl Oral Sci Asunto de la revista: ODONTOLOGIA Año: 2013 Tipo del documento: Article País de afiliación: Brasil