Your browser doesn't support javascript.
loading
Human cardiac 31P magnetic resonance spectroscopy at 7 Tesla.
Rodgers, Christopher T; Clarke, William T; Snyder, Carl; Vaughan, J Thomas; Neubauer, Stefan; Robson, Matthew D.
Afiliación
  • Rodgers CT; Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Level 0, John Radcliffe Hospital, Oxford, United Kingdom.
Magn Reson Med ; 72(2): 304-15, 2014 Aug.
Article en En | MEDLINE | ID: mdl-24006267
ABSTRACT

PURPOSE:

Phosphorus magnetic resonance spectroscopy ((31)P-MRS) affords unique insight into cardiac energetics but has a low intrinsic signal-to-noise ratio (SNR) in humans. Theory predicts an increased (31)P-MRS SNR at 7T, offering exciting possibilities to better investigate cardiac metabolism. We therefore compare the performance of human cardiac (31)P-MRS at 7T to 3T, and measure T1s for (31)P metabolites at 7T.

METHODS:

Matched (31)P-MRS data were acquired at 3T and 7T, on nine normal volunteers. A novel Look-Locker CSI acquisition and fitting approach was used to measure T1s on six normal volunteers.

RESULTS:

T1s in the heart at 7T were phosphocreatine (PCr) 3.05 ± 0.41s, γ-ATP 1.82 ± 0.09s, α-ATP 1.39 ± 0.09s, ß-ATP 1.02 ± 0.17s and 2,3-DPG (2,3-diphosphoglycerate) 3.05 ± 0.41s (N = 6). In the field comparison (N = 9), PCr SNR increased 2.8× at 7T relative to 3T, the Cramer-Ráo uncertainty (CRLB) in PCr concentration decreased 2.4×, the mean CRLB in PCr/ATP decreased 2.7× and the PCr/ATP SD decreased 2×.

CONCLUSION:

Cardiac (31)P-MRS at 7T has higher SNR and the spectra can be quantified more precisely than at 3T. Cardiac (31)P T1s are shorter at 7T than at 3T. We predict that 7T will become the field strength of choice for cardiac (31)P-MRS.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Algoritmos / Imagen por Resonancia Magnética / Espectroscopía de Resonancia Magnética / Compuestos de Fósforo / Miocardio Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Adult / Humans / Male Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2014 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Algoritmos / Imagen por Resonancia Magnética / Espectroscopía de Resonancia Magnética / Compuestos de Fósforo / Miocardio Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Adult / Humans / Male Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2014 Tipo del documento: Article País de afiliación: Reino Unido