Your browser doesn't support javascript.
loading
Evaluation of pH and calcium ion release of a dual-cure bisphenol A ethoxylate dimethacrylate/mineral trioxide aggregate-based root-end filling material.
Linhares, Giane da Silva; Cenci, Maximiliano Sérgio; Knabach, César Blaas; Oliz, Camila Mizette; Vieira, Mariana Antunes; Ribeiro, Anderson Schwingel; Zanchi, César Henrique; Jacinto, Rogério Castilho.
Afiliación
  • Linhares Gda S; Dental School, Federal University of Pelotas, Pelotas, Rio Grande do Sul, Brazil.
J Endod ; 39(12): 1603-6, 2013 Dec.
Article en En | MEDLINE | ID: mdl-24238456
ABSTRACT

INTRODUCTION:

The incorporation of light-curable resins has been proposed for mineral trioxide aggregate (MTA) to improve its properties and reduce its setting time. The aim of the present study was to assess the pH and calcium ion release of an experimental bisphenol A ethoxylate dimethacrylate/MTA-based root-end filling material (E-MTA) in comparison with white MTA Angelus (Angelus, Londrina, PR, Brazil) (W-MTA) and to evaluate the influence of the addition of calcium chloride (CaCl2) on these properties.

METHODS:

Polyethylene tubes filled with the materials were immersed in deionized water for the measurement of pH (digital pH meter) and calcium release (atomic absorption spectrophotometry). The evaluations were performed at 3 and 24 hours and 7, 15, and 30 days. Data were measured using 2-way repeated measures of variance followed by the Holm-Sidak method (P < .05).

RESULTS:

All materials presented a reduction in the pH and released calcium ions during the 30 days of the study. E-MTA showed a significantly lower calcium ion release capacity when compared with W-MTA (P < .05). The calcium release of E-MTA + 5% CaCl2 was similar to W-MTA (P > .05).

CONCLUSIONS:

The monomer bisphenol A ethoxylate dimethacrylate added to MTA formed a material with a lower capacity of calcium release than W-MTA despite maintaining a similar pH. However, the addition of CaCl2 improved the calcium release of this material.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Óxidos / Obturación Retrógrada / Materiales de Obturación del Conducto Radicular / Calcio / Silicatos / Compuestos de Calcio / Compuestos de Aluminio / Metacrilatos Límite: Humans Idioma: En Revista: J Endod Año: 2013 Tipo del documento: Article País de afiliación: Brasil

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Óxidos / Obturación Retrógrada / Materiales de Obturación del Conducto Radicular / Calcio / Silicatos / Compuestos de Calcio / Compuestos de Aluminio / Metacrilatos Límite: Humans Idioma: En Revista: J Endod Año: 2013 Tipo del documento: Article País de afiliación: Brasil