Your browser doesn't support javascript.
loading
Simultaneous quantification of mefloquine (+)- and (-)-enantiomers and the carboxy metabolite in dried blood spots by liquid chromatography/tandem mass spectrometry.
Geditz, Mirjam C K; Lindner, Wolfgang; Lämmerhofer, Michael; Heinkele, Georg; Kerb, Reinhold; Ramharter, Michael; Schwab, Matthias; Hofmann, Ute.
Afiliación
  • Geditz MC; Dr. Margarete Fischer-Bosch Institute of Clinical Pharmacology and University of Tuebingen, Auerbachstrasse 112, 70376 Stuttgart, Germany.
  • Lindner W; Department of Analytical Chemistry, University of Vienna, Währinger Straße 38, 1090 Vienna, Austria.
  • Lämmerhofer M; Institute of Pharmaceutical Science, University of Tuebingen, Auf der Morgenstelle 8, 72076 Tuebingen, Germany.
  • Heinkele G; Dr. Margarete Fischer-Bosch Institute of Clinical Pharmacology and University of Tuebingen, Auerbachstrasse 112, 70376 Stuttgart, Germany.
  • Kerb R; Dr. Margarete Fischer-Bosch Institute of Clinical Pharmacology and University of Tuebingen, Auerbachstrasse 112, 70376 Stuttgart, Germany.
  • Ramharter M; Department of Medicine I, Division of Infectious Diseases and Tropical Medicine, Medical University Vienna, Währinger Gürtel 18-20, 1090 Vienna, Austria; Institut für Tropenmedizin, Universitaet Tuebingen, Wilhelmstrasse 27, 72074 Tuebingen, Germany.
  • Schwab M; Dr. Margarete Fischer-Bosch Institute of Clinical Pharmacology and University of Tuebingen, Auerbachstrasse 112, 70376 Stuttgart, Germany; Department of Clinical Pharmacology, University Hospital, Auf der Morgenstelle 8, 72076 Tuebingen, Germany.
  • Hofmann U; Dr. Margarete Fischer-Bosch Institute of Clinical Pharmacology and University of Tuebingen, Auerbachstrasse 112, 70376 Stuttgart, Germany. Electronic address: ute.hofmann@ikp-stuttgart.de.
Article en En | MEDLINE | ID: mdl-24315337

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Mefloquina / Cromatografía Liquida / Espectrometría de Masas en Tándem / Pruebas con Sangre Seca Tipo de estudio: Diagnostic_studies / Guideline Límite: Female / Humans / Pregnancy Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2014 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Mefloquina / Cromatografía Liquida / Espectrometría de Masas en Tándem / Pruebas con Sangre Seca Tipo de estudio: Diagnostic_studies / Guideline Límite: Female / Humans / Pregnancy Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2014 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Países Bajos