Your browser doesn't support javascript.
loading
Preoperative implant selection for two stage breast reconstruction with 3D imaging.
Szychta, Pawel; Raine, Cameron; Butterworth, Mark; Stewart, Ken; Witmanowski, Henryk; Zadrozny, Marek; Rykala, Jan.
Afiliación
  • Szychta P; Department of Oncological Surgery and Breast Diseases, Polish Mother's Memorial Hospital-Research Institute, Lodz, Poland; Department of Plastic and Reconstructive Surgery, St John's University Hospital, Howden Road West, Livingston EH54 6PP, United Kingdom; Department of Plastic Surgery, Centre of
  • Raine C; Department of Plastic and Reconstructive Surgery, St John's University Hospital, Howden Road West, Livingston EH54 6PP, United Kingdom.
  • Butterworth M; Department of Plastic and Reconstructive Surgery, St John's University Hospital, Howden Road West, Livingston EH54 6PP, United Kingdom.
  • Stewart K; Department of Plastic and Reconstructive Surgery, St John's University Hospital, Howden Road West, Livingston EH54 6PP, United Kingdom.
  • Witmanowski H; Department of Plastic, Reconstructive and Aesthetic Surgery, Collegium Medicum, University Hospital, Bydgoszcz, Poland; Department of Physiology, University of Medical Sciences, Poznan, Poland.
  • Zadrozny M; Department of Oncological Surgery and Breast Diseases, Polish Mother's Memorial Hospital-Research Institute, Lodz, Poland.
  • Rykala J; Department of Plastic, Reconstructive and Aesthetic Surgery, 1st University Hospital, Lodz, Poland.
Comput Biol Med ; 44: 136-43, 2014 Jan.
Article en En | MEDLINE | ID: mdl-24377697
Implants used for two-stage breast reconstruction are selected exclusively on the basis of the directly measured linear parameters. Therefore, the relevant implant is not always chosen despite the wide range of available products. The aim was to analyze the clinical usefulness of three-dimensional (3D) imaging in the breast implant selection. In 50 patients after unilateral two-stage breast reconstruction, height, width, projection and total volume of both breasts were triply obtained with measuring tape (anthropometric method), thermoplastic casting (thermoplastic method) and 3D imaging (optical method). We measured skin fold thickness with skin caliper. In the optical method, we subtracted the covering tissues and calculated the parameter - "estimated breast implant volume" (EBIV), together with the corresponding "anthropometrically estimated breast implant volume" (aEBIV) in the anthropometric method. Reliability of the three methods was described as repeatability and accuracy, both quantified with parameters: "technical error measurement" (TEM) and "reliability factor" (R). Repeatability showed variation among the repeated measurements. Accuracy determined variability between the real volume of the implant used for reconstruction and the obtained volumetric parameters. Repeatability was the highest for the optical method, comparing to anthropometric and thermoplastic methods (p<0.0001). Accuracy was the highest in the optical method for EBIV, comparing to aEBIV in the anthropometric method and the total volume in three methods (p<0.0001). Level of accuracy for EBIV was in the range of variability among the commercially available implants (p>0.05). In conclusion, implants for breast reconstruction are precisely selected with the 3D scanning method, in comparison to widely used direct measurements or thermoplastic casting.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cuidados Preoperatorios / Implantes de Mama / Implantación de Mama / Imagenología Tridimensional Tipo de estudio: Clinical_trials / Observational_studies Límite: Female / Humans Idioma: En Revista: Comput Biol Med Año: 2014 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cuidados Preoperatorios / Implantes de Mama / Implantación de Mama / Imagenología Tridimensional Tipo de estudio: Clinical_trials / Observational_studies Límite: Female / Humans Idioma: En Revista: Comput Biol Med Año: 2014 Tipo del documento: Article Pais de publicación: Estados Unidos