Your browser doesn't support javascript.
loading
Development of an aptamer-based impedimetric bioassay using microfluidic system and magnetic separation for protein detection.
Wang, Yixian; Ye, Zunzhong; Ping, Jianfeng; Jing, Shunru; Ying, Yibin.
Afiliación
  • Wang Y; College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, PR China.
  • Ye Z; College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, PR China.
  • Ping J; College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, PR China.
  • Jing S; College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, PR China.
  • Ying Y; College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, PR China. Electronic address: ybying@zju.edu.cn.
Biosens Bioelectron ; 59: 106-11, 2014 Sep 15.
Article en En | MEDLINE | ID: mdl-24709326
ABSTRACT
An aptamer-based impedimetric bioassay using the microfluidic system and magnetic separation was developed for the sensitive and rapid detection of protein. The microfluidic impedance device was fabricated through integrating the gold interdigitated array microelectrode into a flow cell made of polydimethylsiloxane (PDMS). Aptamer modified magnetic beads were used to capture and separate the target protein, and concentrated into a suitable volume. Then the complexes were injected into the microfluidic flow cell for impedance measurement. To demonstrate the high performance of this novel detection system, thrombin was employed as the target protein. The results showed that the impedance signals at the frequency of 90 kHz have a good linearity with the concentrations of thrombin in a range from 0.1 nM to 10nM and the detection limit is 0.01 nM. Compared with the reported impedimetric aptasensors for thrombin detection, this method possesses several advantages, such as the increasing sensitivity, improving reproducibility, reducing sample volume and assay time. All these demonstrate the proposed detection system is an alternative way to enable sensitive, rapid and specific detection of protein.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Trombina / Técnicas Biosensibles / Técnicas Analíticas Microfluídicas / Aptámeros de Nucleótidos Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Humans Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2014 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Trombina / Técnicas Biosensibles / Técnicas Analíticas Microfluídicas / Aptámeros de Nucleótidos Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Humans Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2014 Tipo del documento: Article
...