Your browser doesn't support javascript.
loading
Two Methods of Hemodynamic and Volume Status Assessment in Critically Ill Patients: A Study of Disagreement.
Eiferman, Daniel S; Davido, H Tracy; Howard, James M; Gerckens, Jennifer; Evans, David C; Cook, Charles H; Stawicki, S P A.
Afiliación
  • Eiferman DS; Department of Surgery, Division of Trauma, Critical Care, and Burn, Ohio State University Wexner Medical Center, Columbus, OH, USA daniel.eiferman@osumc.edu.
  • Davido HT; Department of Surgery, Division of Trauma, Critical Care, and Burn, Ohio State University Wexner Medical Center, Columbus, OH, USA.
  • Howard JM; Department of Surgery, Division of Trauma, Critical Care, and Burn, Ohio State University Wexner Medical Center, Columbus, OH, USA.
  • Gerckens J; Department of Surgery, Division of Trauma, Critical Care, and Burn, Ohio State University Wexner Medical Center, Columbus, OH, USA.
  • Evans DC; Department of Surgery, Division of Trauma, Critical Care, and Burn, Ohio State University Wexner Medical Center, Columbus, OH, USA.
  • Cook CH; Department of Surgery, Division of Trauma, Critical Care, and Burn, Ohio State University Wexner Medical Center, Columbus, OH, USA.
  • Stawicki SP; Department of Surgery, Division of Trauma, Critical Care, and Burn, Ohio State University Wexner Medical Center, Columbus, OH, USA.
J Intensive Care Med ; 31(2): 113-7, 2016 Feb.
Article en En | MEDLINE | ID: mdl-24756310
INTRODUCTION: The invasive nature and potential complications associated with pulmonary artery (PA) catheters (PACs) have prompted the pursuit of less invasive monitoring options. Before implementing new hemodynamic monitoring technologies, it is important to determine the interchangeability of these modalities. This study examines monitoring concordance between the PAC and the arterial waveform analysis (AWA) hemodynamic monitoring system. METHODS: Critically ill patients undergoing hemodynamic monitoring with PAC were simultaneously equipped with the FloTrac AWA system (both from Edwards Lifesciences, Irvine, California). Data were concomitantly obtained for hemodynamic variables. Bland-Altman methodology was used to assess CO measurement bias and κ coefficent to show discrepancies in intravascular volume. RESULTS: Significant measurement bias was observed in both CO and intravascular volume status between the 2 techniques (mean bias, -1.055 ± 0.263 liter/min, r = 0.481). There was near-complete lack of agreement regarding the need for intravenous volume administration (κ = 0.019) or the need for vasoactive agent administration (κ = 0.015). CONCLUSIONS: The lack of concordance between PAC and AWA in critically ill surgical patients undergoing active resuscitation raises doubts regarding the interchangeability and relative accuracy of these modalities in clinical use. Lack of awareness of these limitations can lead to errors in clinical decision making when managing critically ill patients.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arteria Pulmonar / Cuidados Críticos / Hemodinámica / Monitoreo Fisiológico Tipo de estudio: Prognostic_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Intensive Care Med Asunto de la revista: TERAPIA INTENSIVA Año: 2016 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arteria Pulmonar / Cuidados Críticos / Hemodinámica / Monitoreo Fisiológico Tipo de estudio: Prognostic_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Intensive Care Med Asunto de la revista: TERAPIA INTENSIVA Año: 2016 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos