Breast-specific gamma imaging is a cost effective and efficacious imaging modality when compared with MRI.
Johnson, Nathalie; Sorenson, Leslie; Bennetts, Laura; Winter, Karen; Bryn, Sally; Johnson, William; Glissmeyer, Margie; Garreau, Jennifer; Blanchard, Deb.
Afiliación
  • Johnson N; Legacy Cancer Institute and Legacy Breast Health Center, Good Samaritan Breast Health Center, 1040 NW 22nd Avenue, Portland, OR 97210, USA. Electronic address: nemtipi@aol.com.
  • Sorenson L; Legacy Cancer Institute and Legacy Breast Health Center, Good Samaritan Breast Health Center, 1040 NW 22nd Avenue, Portland, OR 97210, USA.
  • Bennetts L; Legacy Cancer Institute and Legacy Breast Health Center, Good Samaritan Breast Health Center, 1040 NW 22nd Avenue, Portland, OR 97210, USA.
  • Winter K; Legacy Cancer Institute and Legacy Breast Health Center, Good Samaritan Breast Health Center, 1040 NW 22nd Avenue, Portland, OR 97210, USA.
  • Bryn S; Legacy Cancer Institute and Legacy Breast Health Center, Good Samaritan Breast Health Center, 1040 NW 22nd Avenue, Portland, OR 97210, USA.
  • Johnson W; Legacy Cancer Institute and Legacy Breast Health Center, Good Samaritan Breast Health Center, 1040 NW 22nd Avenue, Portland, OR 97210, USA.
  • Glissmeyer M; Legacy Cancer Institute and Legacy Breast Health Center, Good Samaritan Breast Health Center, 1040 NW 22nd Avenue, Portland, OR 97210, USA.
  • Garreau J; Legacy Cancer Institute and Legacy Breast Health Center, Good Samaritan Breast Health Center, 1040 NW 22nd Avenue, Portland, OR 97210, USA.
  • Blanchard D; Legacy Cancer Institute and Legacy Breast Health Center, Good Samaritan Breast Health Center, 1040 NW 22nd Avenue, Portland, OR 97210, USA.
Am J Surg ; 207(5): 698-701; discussion 701, 2014 May.
Article en En | MEDLINE | ID: mdl-24791629
ABSTRACT

BACKGROUND:

Both MRI and breast-specific gamma imaging are tools for surgical planning in newly diagnosed breast cancer. Breast-specific gamma imaging (BSGI) is used less frequently although it is of similar utility and lower cost. We compared the diagnostic and cost efficacy of BSGI with MRI.

METHODS:

Retrospective review of 1,480 BSGIs was performed in a community breast health center, 539 had a new diagnosis of cancer, 75 patients having both MRI and BSGI performed within 2 months of each other. Institutional charges for BSGI ($850) and MRI ($3,381) were noted.

RESULTS:

BSGI had a sensitivity of 92%, specificity of 73%, positive predictive value of 78%, and negative predictive value of 90%. This compared favorably with MRI that had sensitivity of 89%, specificity 54%, positive predictive value 67%, and negative predictive value 83%. The accuracy of BSGI was higher at 82% vs MRI at 72%. Total cost of MRI imaging was $253,575 vs BSGI at $63,750.

CONCLUSIONS:

BSGI is a cost-effective and accurate imaging study for further evaluation of dense breast tissue and new diagnosis of cancer.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias de la Mama / Imagen por Resonancia Magnética / Tecnecio Tc 99m Sestamibi / Precios de Hospital / Radiofármacos / Rayos gamma Tipo de estudio: Diagnostic_studies / Evaluation_studies / Health_economic_evaluation / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Female / Humans Idioma: En Revista: Am J Surg Año: 2014 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias de la Mama / Imagen por Resonancia Magnética / Tecnecio Tc 99m Sestamibi / Precios de Hospital / Radiofármacos / Rayos gamma Tipo de estudio: Diagnostic_studies / Evaluation_studies / Health_economic_evaluation / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Female / Humans Idioma: En Revista: Am J Surg Año: 2014 Tipo del documento: Article