Right atrial pressure alterations during echocardiography-guided-catheterization predict tricuspid valvular impairment: a novel method for the creation of a rabbit model of Staphylococcus aureus endocarditis.
Cardiovasc Ultrasound
; 12: 21, 2014 Jun 20.
Article
en En
| MEDLINE
| ID: mdl-24950856
BACKGROUND: We previously reported the use of a catheter system to damage the tricuspid valve and create infectious endocarditis (IE) in an animal model. The current study aims to create a faint IE model suitable for antibiotic prophylaxis using a low bacterial inoculum. We also aim to explore a way to quantitatively assess valvular impairment and to predict the success of the IE models during catheterization. METHODS: Ninety rabbits were assigned to two groups according to the density of bacteria inoculated (1 × 10(5) CFU for Group A and 1 × 10(4) CFU for Group B). A catheter system consisting of a polyethylene catheter and a guide wire were used to damage the valve. The catheter system was passed through the rabbits' tricuspid valves under echocardiographic guidance. A pressure transducer was used to assess right atrial pressure (P(RA)) before and just after valvular damage to calculate the pressure alterations (ΔP(RA)). The animals in group A and B were divided into 3 subgroups according to the ΔP(RA) (0-5 mmHg for Groups A1 and B1; 5-10 mmHg for Groups A2 and B2; 10-15 mmHg for Groups A3 and B3). Staphylococcus aureus (ATCC 29213) inoculation was performed 24 hr after cardiac catheterization. RESULTS: Faint IE was confirmed in 20%, 93.3%, 26.7%, 6.7%, 20%, and 33.3% of the rabbits in Groups A1, A2, A3, B1, B2, and B3, respectively. There was no difference in the LV/RV ratio and VTR of the No-IE, faint-IE, and severe IE animals. Faint IE rabbits had a larger ΔPRA than No-IE rabbits (7.81 ± 1.21 vs. 2.48 ± 1.0, P < 0.01, for Group A; 7.60 ± 1.32 vs. 2.98 ± 1.08, P < 0.01, for Group B). The ΔPRA of severe IE and faint IE rabbits was significantly different (13.11 ± 1.31 vs. 7.81 ± 1.21, P < 0.01, for Group A; 12.73 ± 1.44 vs.7.60 ± 1.32, P < 0.01, for Group B). CONCLUSION: ΔP(RA) could be used to assess valvular impairment. Controlling the value of ΔP(RA) during catheterization and inoculating of an appropriate dose of bacteria was associated with a successful IE model.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Insuficiencia de la Válvula Tricúspide
/
Ecocardiografía
/
Cateterismo Cardíaco
/
Endocarditis Bacteriana
/
Presión Atrial
Tipo de estudio:
Prognostic_studies
/
Risk_factors_studies
Límite:
Animals
Idioma:
En
Revista:
Cardiovasc Ultrasound
Asunto de la revista:
ANGIOLOGIA
/
CARDIOLOGIA
/
DIAGNOSTICO POR IMAGEM
Año:
2014
Tipo del documento:
Article
Pais de publicación:
Reino Unido