Your browser doesn't support javascript.
loading
Determination of a deuterohemin-peptide conjugate in rat plasma by liquid chromatography-tandem mass spectrometry and application to a preclinical pharmacokinetic study.
Wang, Hao; Sun, Yantong; Guo, Wei; Fang, Chunxue; Fawcett, J Paul; Li, Wei; Gao, Yin; Yang, Yan; Gu, Jingkai.
Afiliación
  • Wang H; College of Life Science, Jilin University, Changchun 130012, PR China.
  • Sun Y; School of Pharmaceutical Sciences, Jilin University, Changchun 130021, PR China.
  • Guo W; College of Chemistry, Jilin University, Changchun 130021, PR China.
  • Fang C; College of Life Science, Jilin University, Changchun 130012, PR China.
  • Fawcett JP; School of Pharmacy, University of Otago, PO Box 56, Dunedin, New Zealand.
  • Li W; College of Life Science, Jilin University, Changchun 130012, PR China.
  • Gao Y; Department of Medicine, Division of Rheumatology, Queen's University, Kingston, Ontario, Canada.
  • Yang Y; College of Life Science, Jilin University, Changchun 130012, PR China. Electronic address: yyan@jlu.edu.cn.
  • Gu J; Research Center for Drug Metabolism, Jilin University, Changchun 130012, PR China; Clinical Pharmacology Center, Research Institute of Translational Medicine, The First Hospital of Jilin University, Changchun 130061, PR China. Electronic address: gujk@mail.jlu.edu.cn.
J Pharm Biomed Anal ; 98: 401-6, 2014 Sep.
Article en En | MEDLINE | ID: mdl-25005890
ABSTRACT
The deuterohemin-peptide conjugate (DhHP-6) is a microperoxidase mimetic, which has demonstrated substantial benefits in vivo as a scavenger of reactive oxygen species. This paper reports the development of a sensitive and rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the determination of DhHP-6 in rat plasma using triptorelin as an internal standard (IS). 50µL plasma was used in sample preparation, and a simple protein precipitation procedure with acetonitrile was involved. Satisfactory peak shapes of analyte and IS were obtained on an Agilent HC-C18 column by using a gradient elution with 10mM ammonium acetate-0.5% formic acid (vv) and acetonitrile, there was no significant interference impacting the determination. A calibration curve obtained from this method was linear within the concentration range 10-3000ng/mL with intra- and inter-day precisions of 4.2-6.8% and 3.2-8.9%, respectively and accuracy of -1.3% to 2.1%. The recovery was above 80% with low matrix effects. The method was successfully applied to support a preclinical pharmacokinetic study in rat.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Oligopéptidos / Plasma / Hemina Límite: Animals Idioma: En Revista: J Pharm Biomed Anal Año: 2014 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Oligopéptidos / Plasma / Hemina Límite: Animals Idioma: En Revista: J Pharm Biomed Anal Año: 2014 Tipo del documento: Article