Your browser doesn't support javascript.
loading
Quantification of stenotic mitral valve area and diagnostic accuracy of mitral stenosis by dual-source computed tomography in patients with atrial fibrillation: comparison with cardiovascular magnetic resonance and transthoracic echocardiography.
Kim, Song Soo; Ko, Sung Min; Song, Meong Gun; Chee, Hyun Kun; Kim, Jun Suk; Hwang, Hweung Kon; Lee, Jae-Hwan.
Afiliación
  • Kim SS; Department of Radiology, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon, Korea, haneul88@hanmail.net.
Int J Cardiovasc Imaging ; 31 Suppl 1: 103-14, 2015 Jun.
Article en En | MEDLINE | ID: mdl-25011534
This study aimed to evaluate the utility of dual-source computed tomography (DSCT) for quantification of the mitral valve area (MVA) in patients with atrial fibrillation (AF) and mitral stenosis (MS) and to compare the results of DSCT with those of cardiovascular magnetic resonance (CMR) and transthoracic echocardiography (TTE). One hundred-two patients with AF and MS who had undergone electrocardiography-gated DSCT, TTE and CMR prior to operation were retrospectively enrolled. The MVA was planimetrically determined by DSCT, CMR, and TTE, as well as by Doppler TTE using the pressure half-time method (TTE-PHT). Agreement, relationship between measurements, and the highest accuracy were evaluated using Bland-Altman, Pearson correlation, and receiver operating characteristic analyses. The MVA on DSCT (mean, 1.27 ± 0.27 cm(2)) was significantly larger than that on CMR (1.15 ± 0.28 cm(2), P < 0.05), TTE-planimetry and TTE-PHT (1.16 ± 0.28 and 1.07 ± 0.30 cm(2), respectively; P < 0.05). TTE-planimetry had better correlation with planimetry on DSCT and CMR (r = 0.65 and 0.67, respectively; P < 0.05) than TTE-PHT (r = 0.51 and 0.55, respectively; P < 0.05). Using an MVA of 1.0 cm(2) on TTE-planimetry and TTE-PHT as the reference, the optimal thresholds for detecting severe MS on DSCT was 1.19 cm(2). The planimetry of the MVA measured by DSCT may be a reliable, alternative method for the quantification of MS in patients with AF.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fibrilación Atrial / Imagen por Resonancia Magnética / Ecocardiografía / Tomografía Computarizada por Rayos X / Válvula Mitral / Estenosis de la Válvula Mitral Tipo de estudio: Diagnostic_studies / Evaluation_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Int J Cardiovasc Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2015 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fibrilación Atrial / Imagen por Resonancia Magnética / Ecocardiografía / Tomografía Computarizada por Rayos X / Válvula Mitral / Estenosis de la Válvula Mitral Tipo de estudio: Diagnostic_studies / Evaluation_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Int J Cardiovasc Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2015 Tipo del documento: Article Pais de publicación: Estados Unidos