Low torque levels can initiate a removal of the passivation layer and cause fretting in modular hip stems.
Jauch, S Y; Coles, L G; Ng, L V; Miles, A W; Gill, H S.
Afiliación
  • Jauch SY; Centre for Orthopaedic Biomechanics, Department of Mechanical Engineering, University of Bath, Bath, United Kingdom. Electronic address: s.y.jauch@bath.ac.uk.
  • Coles LG; Centre for Orthopaedic Biomechanics, Department of Mechanical Engineering, University of Bath, Bath, United Kingdom.
  • Ng LV; Centre for Orthopaedic Biomechanics, Department of Mechanical Engineering, University of Bath, Bath, United Kingdom.
  • Miles AW; Centre for Orthopaedic Biomechanics, Department of Mechanical Engineering, University of Bath, Bath, United Kingdom.
  • Gill HS; Centre for Orthopaedic Biomechanics, Department of Mechanical Engineering, University of Bath, Bath, United Kingdom.
Med Eng Phys ; 36(9): 1140-6, 2014 Sep.
Article en En | MEDLINE | ID: mdl-25051900
ABSTRACT
Taper connections of modular hip prostheses are at risk of fretting and corrosion, which can result in reduced implant survival. The purpose of this study was to identify the minimum torque required to initiate a removal of the passivation layer at the taper interface as a function of assembly force and axial load. Titanium stems and cobalt-chromium heads were assembled with peak impaction forces of 4.5 kN or 6.0 kN and then mounted on a materials testing machine whilst immersed in Ringer's solution. The stems were subjected to a static axial load (1 kN or 3 kN) along the taper axis. After a period of equilibration, a torque ramp from 0 to 15 Nm was manually applied and the galvanic potential was continuously recorded. Prostheses assembled with a force of 6 kN required a significantly higher torque to start a removal of the passivation layer compared to those assembled with 4.5 kN (7.23±0.55 Nm vs. 3.92±0.97 Nm, p=0.029). No influence of the axial load on the fretting behaviour was found (p=0.486). The torque levels, which were demonstrated to initiate surface damage under either assembly force, can be readily reached during activities of daily living. The damage will be intensified in situations of large weight and high activity of the patient or malpositioning of the prosthesis.